subject
Engineering, 13.12.2021 14:00 shirleyyxo

Consider a water-cooled compressor operating at steady state. In the compressor, R134-a is compresseConsider a water-cooled compressor operating at steady state. In the compressor, R134-a is compressed from state 1 (saturated vapor, 1 bar) to state 2 (8 bar). The mass flow rate of the R134a is 0.9 kg/min while the HT from the compressor
by water cooling is 140 kJ/min. If the power input to the ccompressor is 3 kW, calculate the R134a exit temperature from
the compressord from state 1
(saturated vapor, 1 bar) to state 2 (8 bar). The mass flow rate of the R134a is 0.9 kg/min while the HT from the compressor
by water cooling is 140 kJ/min. If the power input to the ccompressor is 3 kW, calculate the R134a exit temperature from
the compressor

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Apipe with an outside diameter of 15 cm is exposed to an ambient air and surrounding temperature of -20°c. the pipe has an outer surface temperature of 65°c and an emissivity of 0.85. if the rate of heat loss from the pipe surface is 0.95 kw per meter of length, the external convective heat transfer coefficient (h) is: (a) 12.5 w/m"k (b) 18.6 w/mk (c) 23.7 w/mk (d) 27.9 w/mk (e) 33.5 w/mk
Answers: 1
question
Engineering, 04.07.2019 18:20
Inspection for bearing condition will include: (clo4) a)-color b)-smell c)-size d)-none of the above
Answers: 1
question
Engineering, 04.07.2019 19:10
Asteam is contained in a rigid tank with a volume of 1 m3. initially, the pressure and temperature are 7 bar and 500 oc, respectively. the temperature drops due to cooling process. determine: (1) the temperature at which condensation begins in °c, (2) the fraction of the total mass that has condensed when the pressure decreased to 0.5 bar. (3) the volume in m3 occupied by saturated liquid at the final state?
Answers: 3
question
Engineering, 06.07.2019 04:10
Aspherical thermocouple measurement errors a spherical thermocouple made of constantin transfer coefficient between the gas and the thermocouple is h used to measure the temperature of a gas. the heat 400 w/m2 k. calculate the maximum diameter d of the thermocouple if the thermocouple's measurement error should be w 23 within 5% of the initial temperature difference in 5 seconds. for constantin, k 8920 kg/m3, and c 410 j/kg. k.
Answers: 3