subject
Engineering, 11.05.2021 04:10 katie6097

Limestone scrubbing is used to remove SO2 in a flue gas desulfurization (FGD) system. Relevant reactions are given below. A limestone mix is used that consists of 94% CaCO3 and 6% inert material. The actual feed rate of the limestone mix is 36,000 lb/hr. The SO2 in the flue gas is 20,314 lb/hr and the FGD efficiency is 97%. If the resulting sludge has 58% solids, determine the total sludge production rate (lb/hr). Round your answer to the nearest whole number.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:20
An open feedwater heater operates at steady state with liquid entering at inlet 1 with t? = 40°c and pl = 1 .2 mpa. water vapor att2-200°c and p2 = 1.2 mpa enters at inlet 2. saturated liquid water exits with a pressure of pa 1.2 mpa. neglect heat transfer with the surroundings and all kinetic and potential energy effects, determine the mass flow rate of steam at inlet 2 if the mass flow rate of liquid water at inlet 1 is given as 2 kg/s.
Answers: 3
question
Engineering, 06.07.2019 02:30
Around steel bar, made from material with a yield stress of 750mpa, is loaded so that it has stresses co locations of maximum normal stress and maximum shear stress. use maximum shear stress and maximum distortion energy theories to calculate the safety factors for initial yielding failures.
Answers: 3
question
Engineering, 06.07.2019 03:20
What is the maximum height from which a mass of 30 kg can fall on to a flange on the lower end of a vertical rod of length 1.0 m and diameter 20 mm, the upper end being rigidly fixed, if the stress in the rod is not to exceed 80 mpa? the tensile modulus of the rod is 200 gpa.
Answers: 3
question
Engineering, 06.07.2019 04:20
An insulated tank truck containing 50,000 pounds of double-distilled, deionized water at 30 °c is pumped into a closed, refrigerated storage tank maintained at 5 °c in a facility located on top of mount mitchell, north carolina (elevation 6,684 feet & average july temperature of 84 °f). a)-determine the volume of the storage tank required to hold the purified water. b)- determine the initial and final pressure differences that must be overcome by a liquid pump assuming the storage tank initially contains air at 5 °c. assume the air is slowly bled out of the storage tank during the water transfer c.) during a routine operation today, the tank is slightly ruptured by a stainless steel pipe and a water acrosol of droplets begins to spray out of the storage tank. state all assumptions and determine the internal pressure within the water droplets produced
Answers: 1
You know the right answer?
Limestone scrubbing is used to remove SO2 in a flue gas desulfurization (FGD) system. Relevant react...
Questions
question
SAT, 25.11.2020 19:50
Questions on the website: 13722367