During a heavy snowstorm, a new Civil Engineering building at the University of Indiana collected 6 feet of snow on its roof. The Indiana alumni who designed the building forgot to account for snow loads and the storm caused the building to become highly overloaded. As a result, a single column in the middle of the building failed. Luckily no one was hurt, and the failure underwent extensive forensic testing to determine why only a single column failed under the overloading condition. The forensic study concluded that the applied load, the material properties, and all the dimensions for the failed column were exactly the same as the surrounding columns that did not fail. Thus, after millions of dollars spent in research, the University of Indiana Engineers have determined the problem inexplicable. Required:
Explain to the puzzled Hoosiers how a failure of this most likely occurred given the findings of the forensic study.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 19:20
At steady state, air at 200 kpa, 325 k, and mass flow rate of 0.5 kg/s enters an insulated duct having differing inlet and exit cross-sectional areas. the inlet cross-sectional area is 6 cm2. at the duct exit, the pressure of the air is 100 kpa and the velocity is 250 m/s. neglecting potential energy effects and modeling air as an 1.008 kj/kg k, determine ideal gas with constant cp = (a) the velocity of the air at the inlet, in m/s. (b) the temperature of the air at the exit, in k. (c) the exit cross-sectional area, in cm2
Answers: 2
question
Engineering, 04.07.2019 19:20
Determine the time of the day and month of the year at which the peak sensible cooling load occurs for a top floor, north-eastern corner room of an office building in durban for the following conditions: floor area: 8 x 8 x 3 m east and north walls: 115 mm face brick (outside), 20 mm air space, 115 mm ordinary brick (inside) with 15 mm plaster roof construction: suspended plasterboard ceiling, 450 mm air space, 150 mm concrete, 75mm screed, waterproofing no heat transfer across other surfaces window area 3x 1,5 m high in north wall only. ordinary glass with venetian blinds. lights and occupants : from 07: 00 to 18: 00 average light density: 25 w/m2 number of occupants : 5 seated, light office work room temperature 24°c
Answers: 3
question
Engineering, 04.07.2019 19:20
Acompressor compresses a gas, a pump compresses a liquid. for a given pressure ratio, why does it take more work to compress a gas in a compressor than a liquid in a pump? a)- for a given pressure ratio the average specific volume for a gas is much higher than the average specific volume for a liquid. b)- there is no difference. the only difference is the amount of heat generated (not work) c)- for a given pressure ratio the average volurge for a gas is much higher than the average volume for a liquid. d)-there is no difference
Answers: 3
question
Engineering, 06.07.2019 03:30
Abrayton cycle operates with a regenerator on the air-standard with properties evaluated at 400 k. the tem- perature of the air entering the compressor is 350k while the temperature of the air exiting the compressor is 600 k. the temperature of the air entering the turbine is 1600 k. the overall cycle produced 600 kj/kg of net work out. assuming a regenerator effectiveness of 0.8, what is the temperature of the air before heat addition (combustion)? draw this process on a t - s diagram
Answers: 3
You know the right answer?
During a heavy snowstorm, a new Civil Engineering building at the University of Indiana collected 6...
Questions
question
Mathematics, 16.06.2021 04:00
question
Mathematics, 16.06.2021 04:00
Questions on the website: 13722363