subject
Engineering, 05.02.2020 21:40 hervinlouis014

A5-m × 6-m × 8-m room is to be heated by an electrical resistance heater placed in a short duct in the room.

initially, the room is at 15°c, and the local atmospheric pressure is 98 kpa.

the room is losing heat steadily to the outside at a rate of 200 kj/min.

a 300-w fan circulates the air steadily through the duct and the electric heater at an average mass flow rate of 50 kg/min.

the duct can be assumed to be adiabatic, and there is no air leaking in or out of the room.

if it takes 13 min for the room air to reach an average temperature of 25°c, find

(a) the power rating of the electric heater

(b) the temperature rise that the air experiences each time it passes through the heater.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Two flowing streams of argon gas are adiabatically mixed to form a single flow/stream. one stream is 1.5 kg/s at 400 kpa and 200 c while the second stream is 2kg/s at 500 kpa and 100 ? . it is stated that the exit state of the mixed single flow of argon gas is 150 c and 300 kpa. assuming there is no work output or input during the mixing process, does this process violate either the first or the second law or both? explain and state all your assumptions.
Answers: 1
question
Engineering, 04.07.2019 18:10
Afour cylinder four-stroke in-line engine has a stroke of 160mm, connecting rod length of 150mm, a reciprocating mass of 3kg and its firing order is 1-3-4-2. the spacing between cylinders is 100mm. i. show that the engine is in balance with regard to the primary inertia forces and primary 3. a and secondary inertia couples. li determine the out of balance secondary inertia force ii. propose ways of balancing this out of balance force and discuss the challenges that will arise
Answers: 3
question
Engineering, 04.07.2019 19:10
An electric kettle is made out of stainless steel, weighs two pounds (when empty) and is equipped with a heating element that consumes 2 kw of electricity. assuming that the water and the kettle are at the same uniform temperature at any moment of time, calculate the shortest possible time to bring 2 quarts of water from room temperature to the onset of boiling
Answers: 2
question
Engineering, 04.07.2019 19:20
Determine the stoichiometric and actual air-fuel ratios and the mole flue gas composition for combustion with 15% excess air for raw indiana, pennsylvania raw coal.
Answers: 3
You know the right answer?
A5-m × 6-m × 8-m room is to be heated by an electrical resistance heater placed in a short duct in t...
Questions
question
History, 01.12.2020 20:50
question
Mathematics, 01.12.2020 20:50
question
Mathematics, 01.12.2020 20:50
question
Mathematics, 01.12.2020 20:50
question
Mathematics, 01.12.2020 20:50
question
Mathematics, 01.12.2020 20:50
Questions on the website: 13722360