subject
Physics, 27.07.2021 22:10 juansebas35

A person slaps her leg with her hand, which results in her hand coming to rest in a time interval of 2.25 ms2.25 ms from an initial speed of 4.25 m/s4.25 m/s . What is the magnitude of the average contact force exerted on the leg, assuming the total mass of the hand and the forearm to be 1.75 kg1.75 kg

ansver
Answers: 2

Another question on Physics

question
Physics, 21.06.2019 22:00
Aroll in a paper machine is powered by a separately excited dc machine. operating point 1 (under load): the roll typically operates at 764 rpm and must provide 301 nm of torque to oppose the load of the paper. the armature voltage is 230v for this operating point operating point 2 (no load): when the load is removed the speed of the roll increases to 900 rpm (the field characteristics are unchanged) la ea dev m (a) calculate the maximum torque (units of nm) that the motor can supply with this applied voltage (b) calculate the value of the armature resistance, ra (in ohms) (c) at operating point 1 (loaded condition), the field current, i, and the total input power (armature field), are measured to be to be 10 a and 28,600 w respectively. use this information to calculate the value of the field resistance, rf (in ohms). (d) (d) at operating point 1 (loaded condition), calculate the motor efficiency. express your answer as a percent to at least 2 significant digits. (d) if the field voltage is reduced by 1/2, calculate the new stall torque (in nm) of the motor (f). if the field voltage is reduced by 1/2, calculate the new no-load speed (in rad/sec)
Answers: 1
question
Physics, 22.06.2019 11:30
Write down two additional questions about earth's magnetic field that will make your presentation more informative.
Answers: 1
question
Physics, 22.06.2019 13:30
6–43 a food department is kept at 2128c by a refrigerator in an environment at 308c. the total heat gain to the food department is estimated to be 3300 kj/h and the heat rejection in the condenser is 4800 kj/h. determine the power input to the compressor, in kw and the cop of the refrigerator.
Answers: 2
question
Physics, 22.06.2019 16:50
Acommercial refrigerator with refrigerant-134a as the working fluid is used to keep the refrigerated space at -35°c by rejecting waste heat to cooling water that enters the condenser at 18°c at a rate of 0.25 kg/s and leaves at 26°c. the refrigerant enters the condenser at 1.2 mpa and 50°c. if the compressor consumes 3.3 kw of power, determine (a) the mass flow rate of the refrigerant, (b) the refrigeration load, (c) the cop, and (d) the minimum power input to the compressor for the same refrigeration load.
Answers: 2
You know the right answer?
A person slaps her leg with her hand, which results in her hand coming to rest in a time interval of...
Questions
question
Mathematics, 30.11.2021 21:00
question
Mathematics, 30.11.2021 21:00
question
Mathematics, 30.11.2021 21:00
Questions on the website: 13722361