subject
Physics, 17.04.2020 15:08 Emorej22

A diffraction grating is calibrated using the 546.1 nm line of mercury vapor. It is found that the first order line is located at an angle of 45.3degrees. Calculate the number of lines per 1 millimeter for this grating.

Determine: The number of lines per millimeter is = lines/mm

ansver
Answers: 2

Another question on Physics

question
Physics, 22.06.2019 00:30
Ablock of steel has a density of 0.29lbs per cubic inch. if the block has dimensions of 1 inch by 1 inch by 3 inches, what is its weight? a. 0.29lbs b. 0.58lbs c. 0.87lbs d. 1lbs
Answers: 1
question
Physics, 22.06.2019 02:30
Explain the difference between each pair of concepts. a. frequency and relative frequency b. percentage and relative frequency a. select the correct choice below. a. frequency is the total number of observations in a data set. relative frequency is the number of times a particular distinct value occurs. b. frequency is the number of times a particular distinct value occurs. relative frequency is the ratio of the frequency of a value to the total number of observations. c. frequency is the total number of observations in a data set. relative frequency is the ratio of the number of times a particular distinct value occurs to the frequency. d. frequency is the number of times a particular distinct value occurs. relative frequency is the ratio of the frequency of two different values.
Answers: 3
question
Physics, 22.06.2019 21:00
Which of the following statements comparing electron microscopy and light microscopy is false? which of the following statements comparing electron microscopy and light microscopy is false? both the electron microscope and the light microscope use the same wavelengths for illumination. images produced by light microscopes can be in color, whereas electron microscope images are black and white unless they are artificially colored. the electron microscope has greater resolution than the light microscope. electron microscopes can allow examination of viruses and internal cell structures, whereas light microscopes are limited to objects that are 0.5 micrometers and larger. request answer
Answers: 2
question
Physics, 22.06.2019 21:10
Which radioisotope is used in dating geological formations?
Answers: 3
You know the right answer?
A diffraction grating is calibrated using the 546.1 nm line of mercury vapor. It is found that the f...
Questions
question
Mathematics, 24.02.2021 20:00
question
Mathematics, 24.02.2021 20:00
question
Computers and Technology, 24.02.2021 20:00
question
Health, 24.02.2021 20:00
question
Mathematics, 24.02.2021 20:00
question
English, 24.02.2021 20:00
Questions on the website: 13722367