subject
Physics, 08.11.2019 05:31 lindsaynielsen13

Arefrigerator is used to cool water (cp = 4.18 kj/(kg. oc) & density  = 1 kg/l) from 23 oc to 5 oc in a continuous manner. the heat rejected in the condenser is 570 kj/min and the power of the compressor is 2.65 kw. determine: a) the rate at which water is cooled in l/min b) the refrigerator cop

ansver
Answers: 1

Another question on Physics

question
Physics, 22.06.2019 03:00
An internally reversible refrigerator has a modified coefficient of performance accounting for realistic heat transfer processes of where qin is the refrigerator cooling rate, qout is the heat rejection rate, and is the power input. show that copm can be expressed in terms of the reservoir temperatures tc and th, the cold and hot thermal resistances rt,c and rt,h, and qin, as where rtot rt,c rt,h. also, show that the power input may be expressed as 1.39 a household refrigerator operates with cold- and hot-temperature reservoirs of tc 5 c and th 25 c, respectively. when new, the cold and hot side resistances are rc,n 0.05 k/w and rh,n 0.04 k/w, respectively. over time, dust accumulates on the refrigerator’s condenser coil, which is located behind the refrigerator, increasing the hot side resistance to rh,d 0.1 k/w. it is desired to have a refrigerator cooling rate of qin 750 w. using the results of problem 1.38, determine the modified coefficient of performance and the required power input w under (a) clean and (b) dusty coil conditions. internally reversible refrigerator qout qin w high-temperature reservoir low-temperature reservoir th th,i tc,i tc high-temperature side resistance low-temperature side resistance w qin th tc qinrtot tc qinrtot copm tc qinrtot th tc
Answers: 2
question
Physics, 22.06.2019 07:00
The cerebellum controls? thirst sensations sleep-wake cycles hand-eye coordination heart rate and pulse
Answers: 1
question
Physics, 22.06.2019 12:10
Consider a one meter long horizontal pipe with a constant 100 cm^2 cross sectional area. water flows rightward into the pipe at x = 0 with flow velocity 02m/sec at every point within the pipe intake area. at x=1, the rightward flow rate is 0.192 m/sec. assume the water is a conserved quantity in the pipe, so there must be a leak (a sink) somewhere in the pipe. 1. compute net volumetric flow of the source if the system to be in equilibrium. 2. now assume the pipe in the problem has no leaks. compute the net volumetric rate of change for the system.
Answers: 3
question
Physics, 22.06.2019 14:00
Awater balloon launcher uses an elastic band with a spring constant of 115 n/m to use thee launcher you stretch thee band back with a balloon n it the water balloons have a mass of 1.3 kg a) if you stretch the band by 0.8 m, what elastic force will the band exert? b) with the band stretched 0.8 m, how much elastic potential energy is stored in the spring? c) if you release the band, it pushes forward. what is the kinetic energy of the balloon when it reaches the natural length of the band? d) what is the speed of the balloon when it reaches the natural length of the band?
Answers: 1
You know the right answer?
Arefrigerator is used to cool water (cp = 4.18 kj/(kg. oc) & density  = 1 kg/l) from 23 oc to...
Questions
question
Biology, 19.03.2021 01:00
question
English, 19.03.2021 01:00
question
Mathematics, 19.03.2021 01:00
question
Mathematics, 19.03.2021 01:00
question
Biology, 19.03.2021 01:00
Questions on the website: 13722367