Physics, 11.10.2019 00:00 shjsmbee8177

Carbon steel balls (rho = 7833 kg/m3, k = 54 w/m·°c, cp = 0.465 kj/kg·°c, and α = 1.474*10-6 m2 /s) 8 mm in diameter are annealed by heating them first to 900°c in a furnace and then allowing them to cool slowly to 100°c in ambient air at 35°c. if the average heat transfer coefficient is 75 w/m2 ·°c, determine how long the annealing process will take. if 2500 balls are to be annealed per hour, determine the total rate of heat transfer from the balls to the ambient.

ansver
Answers: 2

Another question on Physics

question
Physics, 22.06.2019 05:30
Will give brainliest! which statement best describes the difference between strong nuclear forces and weak nuclear forces? weak nuclear forces are involved when certain types of atoms break down. strong nuclear forces are responsible for holding atoms' nucleus together. weak nuclear forces hold bonds between atoms together. strong nuclear forces hold together the nucleus of an atom. strong nuclear bonds prevent atoms from falling apart. weak nuclear bonds prevent compounds from falling apart. strong nuclear forces are involved in breaking electrons from their shells. weak nuclear forces hold protons in the nucleus.
Answers: 3
question
Physics, 22.06.2019 08:00
What is the average speed of a car that travels 40 mph for 1 hour and 60 mph in another hour?
Answers: 1
question
Physics, 22.06.2019 19:30
Select light for the type of wave, adjust the wavelength so that the light is red, and increase the amplitude of the light to the max. then, select the start button at the source location to begin producing the waves. light is a form of electromagnetic wave, containing oscillating electric and magnetic fields. the wave amplitude detector mentioned above shows how the electric field oscillates in time at the location of the probe. the amplitude of the wave at the location of the probe is equal to the maximum electric field measured. how does the amplitude of the wave depend on the distance from the source?
Answers: 2
question
Physics, 22.06.2019 21:00
Which of the following statements comparing electron microscopy and light microscopy is false? which of the following statements comparing electron microscopy and light microscopy is false? both the electron microscope and the light microscope use the same wavelengths for illumination. images produced by light microscopes can be in color, whereas electron microscope images are black and white unless they are artificially colored. the electron microscope has greater resolution than the light microscope. electron microscopes can allow examination of viruses and internal cell structures, whereas light microscopes are limited to objects that are 0.5 micrometers and larger. request answer
Answers: 2
You know the right answer?
Carbon steel balls (rho = 7833 kg/m3, k = 54 w/m·°c, cp = 0.465 kj/kg·°c, and α = 1.474*10-6 m2 /s)...
Questions
question
History, 02.07.2019 00:30
question
History, 02.07.2019 00:30
question
History, 02.07.2019 00:30
question
Chemistry, 02.07.2019 00:30
Questions on the website: 13722360