subject
Engineering, 30.09.2021 22:00 stichgotrich7159

Measure of the velocity distribution of a fluid flowing in a pipe (laminar flow) are given in the table. the flow rate Q (volume of fluid per second) in the pipe can be calculated by: Use that data in the table to evalute Q.

Use all methods that apply for the problem. You can use computer software as Matlab user-defined
functions or MathCad explicit solution. Compare results and rank methods from best to worse.


Measure of the velocity distribution of a fluid flowing in a pipe (laminar flow) are given in the t

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Refrigerant 134a enters an insulated compressor operating at steady state as saturated vapor at -26°c with a volumetric flow rate of 0.18 m3/s. refrigerant exits at 9 bar, 70°c. changes in kinetic and potential energy from inlet to exit can be ignored. determine the volumetric flow rate at the exit, in m3/s, and the compressor power, in kw.
Answers: 1
question
Engineering, 04.07.2019 18:10
Ariver flows from north to south at 8 km/h. a boat is to cross this river from west to east at a speed of 20 km/h (speed of the boat with respect to the earth/ground). at what angle (in degrees) must the boat be pointed upstream such that it will proceed directly across the river (hint: find the speed of the boat with respect to water/river)? a 288 b. 21.8 c. 326 d. 30.2
Answers: 3
question
Engineering, 04.07.2019 18:10
Compute the pressure drop of 30°c air flowing with a mean velocity of 8 m/s in a circular sheet-metal duct 300 mm in diameter and 15 m long. use a friction factor, f 0.02, and pair = 1.1644 kg/m a. 37.26 pa b. 25.27 pa n c. 29.34 pa d. 30.52 pa
Answers: 1
question
Engineering, 04.07.2019 18:20
Athin walled concentric tube exchanger is used to cool engine oil from 160°c to 60°c with water that is available at 25°c acting as a coolant. the oil and water flow rates are each at 2 kg/s, and the diameter of the inner tube is 0.5 m and the corresponding value of the overall heat transfer coefficient is 250 w/m2. oc. how long must the heat exchanger be to accomplish the desired cooling? cpwater=4.187 kj/kg-candcpengine el=2.035 kj/kg·°c, oil . 120]
Answers: 1
You know the right answer?
Measure of the velocity distribution of a fluid flowing in a pipe (laminar flow) are given in the ta...
Questions
question
History, 22.05.2020 22:07
question
Health, 22.05.2020 22:07
question
World Languages, 22.05.2020 22:08
question
History, 22.05.2020 22:08
Questions on the website: 13722360