subject
Engineering, 18.09.2021 19:40 jackienassiri

Start the Kali VM Use Nmap or Zenmap to scan your Metasploitable VM. The included videos provide a walkthrough of Nmap usage and scanning a target Use Nmap build-in help menu as shown in the videos or refer to https://nmap. org/book/man. html (Links to an external site.) to put together and execute Nmap scan (one scan) with the following options configured Enable script scanning, ports scanning, service scanning, OS detection, enable verbosity AND Export the results in XML format Scan only the Metasploitable VM Save the XML scan results Complete a table with the results. The example table is provided in Excel format The table can be prepopulated with most of the information using the Discover Scripts To download and setup the Discover scripts watch the “Parse Nmap with Discover Scripts” video which provides a step-by-step Hint: The same video walks through also conducting Nmap scan against Metasploitable, saving the results in XML file, using Discover to parse the results, and import them into Excel.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 19:10
What is the main objective of using reheat rankine cycle?
Answers: 3
question
Engineering, 04.07.2019 19:10
Abarometer contains mercury with a density of 13600 kg/m3. atmospheric conditions are 95.8 kpa and 20 °c at 20 °c, the vapor pressure of the mercury is 0.000173 kpa. the column of mercury will rise to a height of most nearly. select one: a)- 0.38 m b)- 0.82 m c)- 0.48 m d)- 0.72 m
Answers: 1
question
Engineering, 04.07.2019 19:10
Apressure vessel with an r/t 20 cannot be treated as thin walled vessel. a)-trune b)- false
Answers: 3
question
Engineering, 04.07.2019 19:20
Acommercial grade cubical freezer, 4 m on a side, has a composite wall consisting of an exterior sheet of 5.0-mm thick plain carbon steel (kst= 60.5 w/m k), an intermediate layer of 100-mm thick polyurethane insulation (kins 0.02 w/m k), and an inner sheet of 5.0- mm thick aluminium alloy (kal polyurethane insulation and both metallic sheets are each characterized by a thermal contact resistance of r 2.5 x 104 m2 k/w. (a) what is the steady-state cooling load that must be maintained by the refrigerator under conditions for which the outer and inner surface temperatures are 25°c and -5°c, respectively? (b) for power saving purpose, which wall material should be increased/reduced in. thickness in order to reduce 50% of the cooling load found in part (a)? redesign the thickness of the proposed material. 177 w/m-k). adhesive interfaces between the q=575.93 w
Answers: 2
You know the right answer?
Start the Kali VM Use Nmap or Zenmap to scan your Metasploitable VM. The included videos provide a w...
Questions
question
Mathematics, 20.04.2021 16:10
question
Mathematics, 20.04.2021 16:10
Questions on the website: 13722362