subject
Engineering, 06.08.2021 02:40 senituliii

problem 2 (25 pts) design a low pass butterworth filter to remove high frequency noise from a signal with a nyquist frequency of 1000 hz meeting the following design requirements: 1. the dynamic error to be less than 0.01 at 500 hz or lower frequencies and 2. the attenuation at 4.5 khz or higher frequencies to be at least 25 db the filter cutolt frequency is to be 1500 hz. take the source and load impedances as 50 n. part a) 10 pts find the order of the butterworth filter required lo mcet the above design criteria. part b) 10 pts find the values of the capacitors and inductors required to construct the filter and draw a circuit dingram of the filter. part c) 5 pts at what lowest frequency this signal must be sampled so that signal aliasing is avoided

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Abrake has a normal braking torque of 2.8 kip in and heat-dissipating cast-iron surfaces whose mass is 40 lbm. suppose a load is brought to rest in 8.0 s from an initial angular speed of 1600 rev/min using the normal braking torque; estimate the temperature rise of the heat dissipating surfaces.
Answers: 3
question
Engineering, 04.07.2019 18:10
Adouble-strand no. 60 roller chain is used to transmit power between a 13-tooth driving sprocket rotating at 300 rev/min and a 52-tooth driven sprocket. a) what is the allowable horsepower of this drive? b) estimate the center-to-center distance if the chain length is 82 pitches. c) estimate the torque and bending force on the driving shaft by the chain if the actual horsepower transmitted is 30 percent less than the corrected (allowable) power.
Answers: 3
question
Engineering, 04.07.2019 18:20
Air is compressed isentropically from an initial state of 300 k and 101 kpa to a final temperature of 1000 k. determine the final pressure using the following approaches: (a) approximate analysis (using properties at the average temperature) (b) exact analysis
Answers: 1
question
Engineering, 04.07.2019 18:20
Refrigerant-134a enters the compressor of a refrigerator as superheated vapor at 0.14 mpa and -10°c at a rate of 0.05 ka/s and leaves at 0.8 mpa and 50°c. the refrigerant is cooied in the condenser to 0.72 mpa and 26'c. it is then throttled to 0.15 mpa. sketch the t-s diagram for the system and evaluate: 6) the rate of heat removai from the refrigerated space (kw), it) the power input to the compressor (kw), ii) the isentropic efficiency of the compressor (%), and iv) the cop of the refrigerator.
Answers: 2
You know the right answer?
problem 2 (25 pts) design a low pass butterworth filter to remove high frequency noise from a signal...
Questions
question
Social Studies, 13.11.2020 23:20
question
Physics, 13.11.2020 23:20
question
Physics, 13.11.2020 23:20
question
Mathematics, 13.11.2020 23:20
Questions on the website: 13722367