subject
Engineering, 02.07.2021 14:00 sabrinaaz

Given a DC volt meter with range 0-10V, 0-25V and 0-50V. The moving coil instrument has an internal resistor of 50Ω and full scale deflection current of 2mA. With the suitable DC

volt meter diagram, derive the equation to measure R1, R2 and R3. Also include calculation of

all the series resistors value in the circuit.​

ansver
Answers: 2

Another question on Engineering

question
Engineering, 03.07.2019 14:10
Amass of m 1.5 kg of steam is contained in a closed rigid container. initially the pressure and temperature of the steam are: p 1.5 mpa and t 240°c (superheated state), respectively. then the temperature drops to t2= 100°c as the result of heat transfer to the surroundings. determine: a) quality of the steam at the end of the process, b) heat transfer with the surroundings. for: p1.5 mpa and t 240°c: enthalpy of superheated vapour is 2900 kj/kg, specific volume of superheated vapour is 0. 1483 m/kg, while for t 100°c: enthalpy of saturated liquid water is 419kj/kg, specific volume of saturated liquid water is 0.001043m/kg, enthalpy of saturated vapour is 2676 kj/kg, specific volume of saturated vapour is 1.672 m/kg and pressure is 0.1 mpa.
Answers: 3
question
Engineering, 04.07.2019 18:10
Water at the rate of 1 kg/s is forced through a tube with a 2.5 cm inner diameter. the inlet water temperature is 15°c, and the outlet water temperature is 50°c. the tube wall temperature is 14°c higher than the local water temperature all along the length of the tube. what is the length of the tube?
Answers: 3
question
Engineering, 04.07.2019 18:20
Refrigerant-134a enters the compressor of a refrigerator as superheated vapor at 0.14 mpa and -10°c at a rate of 0.05 ka/s and leaves at 0.8 mpa and 50°c. the refrigerant is cooied in the condenser to 0.72 mpa and 26'c. it is then throttled to 0.15 mpa. sketch the t-s diagram for the system and evaluate: 6) the rate of heat removai from the refrigerated space (kw), it) the power input to the compressor (kw), ii) the isentropic efficiency of the compressor (%), and iv) the cop of the refrigerator.
Answers: 2
question
Engineering, 04.07.2019 19:10
How to increase the thermal officiency of an ideal simple rankino cycle? among these methods, which one is the best and why?
Answers: 2
You know the right answer?
Given a DC volt meter with range 0-10V, 0-25V and 0-50V. The moving coil instrument has an internal...
Questions
question
Arts, 30.05.2021 16:20
question
English, 30.05.2021 16:20
question
Mathematics, 30.05.2021 16:20
question
Biology, 30.05.2021 16:30
question
Mathematics, 30.05.2021 16:30
question
Advanced Placement (AP), 30.05.2021 16:30
question
Mathematics, 30.05.2021 16:30
Questions on the website: 13722367