subject
Engineering, 25.05.2021 23:10 ari8160

An article gave a scatter plot along with the least squares line of x = rainfall volume (m3) and y = runoff volume (m3) for a particular location. The accompanying values were read from the plot. c) Calculate a point estimate of the true average runoff volume when rainfall volume is 51. (Round your answer to four decimal places.)

(d) Calculate a point estimate of the standard deviation . (Round your answer to two decimal places.)

(e) What proportion of the observed variation in runoff volume can be attributed to the simple linear regression relationship between runoff and rainfall? (Round your answer to four decimal places.)

x 6 12 14 16 23 30 40 52 55 67 72 81 96 112 127

y 4 10 13 14 15 25 27 48 38 46 53 72 82 99 100

ansver
Answers: 3

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Apiston-cylinder with a volume of 0.25 m3 holds 1 kg of air (r 0.287 k/kgk) at a temperature of 100 c. heat transfer to the cylinder causes an isothermal expansion of the piston until the volume triples. how much heat is added to the piston-cylinder?
Answers: 3
question
Engineering, 03.07.2019 19:30
When using the ohmmeter function of a digital multimeter, the leads are placed in what position relative to the component being tested? a. parallel b. control c. series d. line
Answers: 3
question
Engineering, 04.07.2019 18:10
Determine whether or not it is possible to compress air adiabatically from k to 140 kpa and 400 k. what is the entropy change during this process?
Answers: 3
question
Engineering, 04.07.2019 18:20
Along 8-cm diameter steam pipe whose external surface temperature is 900c connects two buildings. the pipe is exposed to ambient air at 70c with a wind speed of 50 km/hr blowing across the pipe. determine the heat loss from the pipe per unit length. (b) air at 500c enters a section of a rectangular duct (15 cm x 20 cm) at an average velocity of 7 m/s. if the walls of the duct are maintained at 100c. a) the length of the tube for an exit temperature of the air to be 40 0c. b)the rate of heat transfer from the air. c) the fan power needed to overcome the pressure drop in this section of the duct.
Answers: 1
You know the right answer?
An article gave a scatter plot along with the least squares line of x = rainfall volume (m3) and y =...
Questions
question
Mathematics, 29.01.2021 02:00
question
Mathematics, 29.01.2021 02:00
question
Mathematics, 29.01.2021 02:00
question
Mathematics, 29.01.2021 02:00
question
Mathematics, 29.01.2021 02:00
question
Mathematics, 29.01.2021 02:00
Questions on the website: 13722363