subject
Engineering, 06.05.2021 05:00 shanaz8199

A balanced bank of delta-connected capacitors is connected in parallel with the load described in Assessment Problem The effect is to place a capacitor in parallel with the load in each phase. The line voltage at the terminals of the load thus remains at 2450 V. The circuit is operating at a frequency of 60 Hz. The capacitors are adjusted so that the magnitude of the line current feeding the parallel combination of the load and capacitor bank is at its minimum. a) What is the size of each capacitor in microfarads?
b) Repeat (a) for wye-connected capacitors
c) What is the magnitude of the line current?
Problem
The magnitude of the line voltage at the terminals of a balanced Y-connected load is 6600 V. The load impedance is 240 − j70 Ω/ϕ. The load is fed from a line that has an impedance of 0.5 + j4 Ω/ϕ.
a) What is the magnitude of the line current?
b) What is the magnitude of the line voltage at the source?

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Courses that are developed by subject matter experts, internal or extemal to the college or university. these programs are marketed by the school (clo2) marks a)-vocational schools b)-vendor training c)-colleges & universities d)-continuing education programs
Answers: 2
question
Engineering, 04.07.2019 18:10
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
question
Engineering, 04.07.2019 18:20
Select any two (2) areas of applications of chain-drive. (clo4) a)-permanent lubrication necessary b)-hydraulic forklift truck operation c)-rigging and heavy moving materials d)-relatively high maintenance costs e)-costlier than belt drives
Answers: 2
question
Engineering, 04.07.2019 18:20
Refrigerant-134a enters the compressor of a refrigerator as superheated vapor at 0.14 mpa and -10°c at a rate of 0.05 ka/s and leaves at 0.8 mpa and 50°c. the refrigerant is cooied in the condenser to 0.72 mpa and 26'c. it is then throttled to 0.15 mpa. sketch the t-s diagram for the system and evaluate: 6) the rate of heat removai from the refrigerated space (kw), it) the power input to the compressor (kw), ii) the isentropic efficiency of the compressor (%), and iv) the cop of the refrigerator.
Answers: 2
You know the right answer?
A balanced bank of delta-connected capacitors is connected in parallel with the load described in As...
Questions
question
History, 24.12.2021 23:40
Questions on the website: 13722363