subject
Engineering, 09.04.2021 03:20 granny57i

The extent to which the tip condition affects the thermal performance of a fin depends on the fin geometry and thermal conductivity, as well as the convection coefficient. Consider an alloyed aluminum (k = 180 W/m ∙ K) rectangular fin whose base temperature is Tb = 100°C. The fin is exposed to a fluid of temperature T[infinity] = 25°C, and a uniform convection coefficient of h = 100 W/m2 ∙ K may be assumed for the fin surface. (a) For a fin of length L = 10 mm, thickness t = 1 mm, and width w >> t, determine the fin heat transfer rate per unit width q;, efficiency ηf effectiveness εf' thermal resistance per unit width Rt. f, and tip temperature T(L) for Cases A and B of Table 3.4. Contrast your results with those based on an infinite fin approximation.
(b) Explore- the effect of variations in L on the heat rate for 3 < L < 50 mm. Also consider the effect of such variations for a stainless steel fin (k = 15 W/m' K)

ansver
Answers: 1

Another question on Engineering

question
Engineering, 03.07.2019 14:10
Line joining liquid phase with liquid and solid phase mixture is known as: a) liquidus b) solidus c) tie line d) none of the mentioned
Answers: 2
question
Engineering, 04.07.2019 18:10
Air is to be cooled in the evaporator section of a refrigerator by passing it over a bank of 0.8-cm-outer-diameter and 0.4-m-long tubes inside which the refrigerant is evaporating at -20°c. air approaches the tube bank in the normal direction at 0°c and 1 atm with a mean velocity of 4 m/s. the tubes are arranged in-line with longitudinal and transverse pitches of sl- st 1.5 cm. there are 30 rows in the flow direction with 15 tubes in each row. determine (a) the refrigeration capacity of this system and (b) pressure drop across the tube bank. evaluate the air properties at an assumed mean temperature of -5°c and 1 atm. is this a good assumption?
Answers: 1
question
Engineering, 04.07.2019 18:10
The thermal expansion or contraction of a given metal is a function of the f a)-density b)-initial temperature c)- temperature difference d)- linear coefficient of thermal expansion e)- final temperature f)- original length
Answers: 2
question
Engineering, 04.07.2019 18:10
Condition monitoring is a major component of. (clo4) a)- predictive maintenance. b)-preventive maintenance c)-proactive maintenance d)-reactive maintenance.
Answers: 1
You know the right answer?
The extent to which the tip condition affects the thermal performance of a fin depends on the fin ge...
Questions
question
Health, 29.01.2020 21:57
question
Mathematics, 29.01.2020 21:58
Questions on the website: 13722367