Engineering, 04.03.2021 19:50 kenniedalany

Absorption: Rods of radioactive waste that are highly active are stored in cooling ponds of purified water. Usually, the rods are stored 20 feet below the surface of the water. We wish to calculate the neutron flux that reaches the surface the water. The total cross- section for an incident, room-temperature neutron onto a 1H nucleus is approximately 35 barns. The total cross-section for an incident, room-temperature neutron onto an oxygen nucleus is approximately 4 barns. A. Calculate the molecular number density of water.
B. Calculate the number density of hydrogen nuclei and the number density of oxygen nuclei.
C. Calculate the macroscopic cross-section (Z) for an incident, room temperature neutron passing through the water.
D. Calculate the mean free path ( (x) ) of a room temperature neutron in water.
E. Calculate the fraction of the radiation emitted from the rods that reach the surface of the water (1(x)/10).

ansver
Answers: 1

Another question on Engineering

question
Engineering, 03.07.2019 14:10
When at a point two solid phase changes to one solid phase on cooling then it is known as a) eutectoid point b) eutectic point c) peritectic point d) peritectoid point
Answers: 3
question
Engineering, 03.07.2019 23:20
Two technicians are discussing the intake air temperature (iat) sensor. technician a says that the computer uses the iat sensor as a backup to the engine coolant temperature (ect) sensor. technician b says that the powertrain control module (pcm) will subtract the calculated amount of fuel if the air measures hot. who is correct
Answers: 3
question
Engineering, 04.07.2019 18:10
For the closed feedwater heater below, feedwater enters state 3 at a pressure of 2000 psia and temperature of 420 °f at a rate of ix10 ibhr. the feedwat extracted steam enters state 1 at a pressure of 1000 psia and enthalpy of 1500 btu/lbm. the extracted er leaves at an enthalpy of 528.7 btu/lbm steam leaves as a saturated liquid. (16) a) determine the mass flow rate of the extraction steam used to heat the feedwater (10) b) determine the terminal temperature difference of the closed feedwater heater
Answers: 3
question
Engineering, 04.07.2019 18:10
Water at 55c flows across a flat plate whose surface temperature is held constant at 95c. if the temperature gradient at the plate's surface for a given value of x is 18 c/mm, find a) local heat transfer coefficient. b) heat flux
Answers: 3
You know the right answer?
Absorption: Rods of radioactive waste that are highly active are stored in cooling ponds of purified...
Questions
question
Biology, 08.01.2021 20:30
question
Mathematics, 08.01.2021 20:30
question
Mathematics, 08.01.2021 20:30
question
Arts, 08.01.2021 20:40
Questions on the website: 13722362