subject
Engineering, 02.03.2021 14:00 dlr1628

8.2 Measurement Methods 8.2.1 Direct Injection of Solvent
The solvent is injected into the sample in a continuous process. The sample is held in a rubber
sleeve thus forcing the flow to be uniaxial.
8.2.2 Centrifuge Flushing
A centrifuge which has been fitted with a special head sprays warm solvent onto the sample.
The centrifugal force then moves the solvent through the sample. The used solvent can be
collected and recycled.
8.2.3 Gas Driven Solvent Extraction
The sample is placed in a pressurized atmosphere of solvent containing dissolved gas. The
solvent fills the pores of sample. When the pressure is decreased, the gas comes out of
solution, expands, and drives fluids out of the rock pore space. This process can be repeated
as many times as necessary.
8.2.4 Soxhlet Extraction
A Soxhlet extraction apparatus is the most common method for cleaning sample, and is
routinely used by most laboratories. As shown in Figure 8.1, toluene is brought to a slow boil
in a Pyrex flask; its vapors move upwards and the core becomes engulfed in the toluene
vapors (at approximately 110°C). Eventual water within the core sample in the thimble will
be vaporized. The toluene and water vapors enter the inner chamber of the condenser, the
cold water circulating about the inner chamber condenses both vapors to immiscible liquids.
Recondensed toluene together with liquid water falls from the base of the condenser onto the
core sample in the thimble; the toluene soaks the core sample and dissolves any oil with
which it come into contact. When the liquid level within the Soxhlet tube reaches the top of
the siphon tube arrangement, the liquids within the Soxhlet tube are automatically emptied bya siphon effect and flow into the boiling flask .the toluene is then ready to start another cycle. A complete extraction may take several days to several weeks in the case of low:API gravity crude or presence of heavy residual hydrocarbon deposit within the core low permeability rock may also require a long extraction time
​

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 19:10
An electric kettle is made out of stainless steel, weighs two pounds (when empty) and is equipped with a heating element that consumes 2 kw of electricity. assuming that the water and the kettle are at the same uniform temperature at any moment of time, calculate the shortest possible time to bring 2 quarts of water from room temperature to the onset of boiling
Answers: 2
question
Engineering, 05.07.2019 23:20
Which one of the following faults cause the coffee in a brewer to keep boiling after the brewing cycle is finished? a. an open circuit in the heating element b. a short circuit at the terminals c. welded contacts on the thermostat d. a leak around the gasket
Answers: 3
question
Engineering, 06.07.2019 03:10
List and describe the attached tools in boxford cnc milling machine? and how many tools were used in your projects explain them?
Answers: 3
question
Engineering, 06.07.2019 03:20
1kg of water contained in a piston-cylinder assembly undergoes two processes in series from an initial state where the pressure is 3.0 bar and the temperature is 150°c process 1-2: the water is compressed isothermally to a volume of 0.25 m^3 with 120 kj of work being done to the system. process 2-3: the water is heated at constant volume to a final pressure of 10 bar. a. find the change in internal energy for the system. b. calculate the amount of heat transferred, in kj. c. sketch both processes on a t-v diagram. (196.33 kj/kg, 76.33 kj)
Answers: 1
You know the right answer?
8.2 Measurement Methods 8.2.1 Direct Injection of Solvent
The solvent is injected into the sam...
Questions
question
Mathematics, 04.02.2020 15:03
question
Mathematics, 04.02.2020 15:03
Questions on the website: 13722360