subject
Engineering, 22.02.2021 07:30 Jana1517

You are going to design an air-conditioning system for winter. On a certain day of February atmospheric temperature is 14°C and relative humidity of air is 50%. Outdoor air enters the system at a steady rate of 20 m3/min, the air is first heated to a temperature of 22°C and then passes through a humidifying section in which hot water is sprayed the exit conditions of air to inside of room are 25°C and 55 percent relative humidity The entire process takes place at a constant pressure (atmospheric pressure)
You are required to find
a) Plot the states on Psychometric charts
b) Power needed to operate the heater
c) The mass flow rate of steam required in the humidifying section
d) Consider various options and suggest a device for spraying of hot water
e) Consider various options and suggest a device for flow of air (How pressure changes can affect the results)

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
question
Engineering, 04.07.2019 19:10
Agas contained within a piston-cylinder assembly e end nation about same energy states, 1 and 2, where pi 10 bar, v undergoes two processes, a and b, between the sam 0.1 m3, ui-400 kj and p2 1 bar, v2 1.0 m2, u2 200 kj: process a: process from 1 to 2 during which the pressure- volume relation is pv constant process b: constant-volume process from state 1 to a pressure of 2 bar, followed by a linear pressure-volume process to +20 0 state 2 kinetic and potential energy effects can be ignored. for each of the processes a and b, (a) sketch the process on p-v coordinates, (b) evaluate the work, in kj, and (c) evaluate process the heat transfer, in kj
Answers: 2
question
Engineering, 04.07.2019 19:20
Acircular pipe of 30mm outside diameter is placed in an airstream at 30 c and latm pressure. the air moves in cross flow over the pipe at 20 m/s, while the outer surface of the pipe is maintained at 110 c. what is the drag force exerted on the pipe per unit length? what is the rate of heat transfer from the pipe per unit length?
Answers: 1
question
Engineering, 04.07.2019 19:20
Afan that can provide air speeds up to 60 m/s is to be used in a low-speed wind tunnel with atmospheric air at 35 c. if one wishes to use the wind tunnel to study flat-plate boundary layer behavior up to reynolds numbes of re 10, what is the minimum plate length that should be used? at what distance from the leading edge would transition occur if the critical reynolds nurnber were rer,e = 5 × 105?
Answers: 2
You know the right answer?
You are going to design an air-conditioning system for winter. On a certain day of February atmosphe...
Questions
question
Chemistry, 12.08.2020 04:01
question
Physics, 12.08.2020 04:01
Questions on the website: 13722367