subject
Engineering, 09.02.2021 01:00 slonzyy8397

The composite wall of an oven consists of three materials, two of which are of known thermal conductivity, kA = 25 W/m ⋅ K and kC = 60 W/m ⋅ K, and known thickness, LA = 0.40 m and LC = 0.20 m. The third material, B, which is sandwiched between materials A and C, is of known thickness, LB = 0.20 m, but unknown thermal conductivity kB. Under steady-state operating conditions, measurementsreveal an outer surface temperature of Ts, o =20ºC, an inner surface temperature of Ts, i= 600ºC, and an oven air temperature ofT¥=800ºC. The inside convection coefficienth is known to be 25 W/(m^2•K). What isthe value of kB?

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Manometers are good examples of measuring instruments, nowadays they are not as common as before. a)-capacitive probe gauges b)-gravitational gauges deformation ) gauges d)-digital gauges
Answers: 1
question
Engineering, 04.07.2019 18:10
Aturning operation is performed with following conditions: rake angle of 12°, a feed of 0.35 mm/rev, and a depth of cut of 1.1 mm. the work piece is aluminum alloy 6061 with t6 heat treatment (a16061-t6). the resultant chip thickness was measured to be 1.0 mm. estimate the cutting force, fc. use shear stress of 207 mpa and coefficient of friction on the tool face of 0.6.
Answers: 1
question
Engineering, 04.07.2019 18:20
Water vapor initially at 10 bar and 400 °c is contained within a piston-cylinder assembly. the water lost heat to the surrounding according to isochoric (iso-volumetric) process until its temperature is 150 °c. the water is then condensed isothermally to saturated liquid. for the water as a system, calculate the work in kj/kg
Answers: 2
question
Engineering, 04.07.2019 19:20
Acommercial grade cubical freezer, 4 m on a side, has a composite wall consisting of an exterior sheet of 5.0-mm thick plain carbon steel (kst= 60.5 w/m k), an intermediate layer of 100-mm thick polyurethane insulation (kins 0.02 w/m k), and an inner sheet of 5.0- mm thick aluminium alloy (kal polyurethane insulation and both metallic sheets are each characterized by a thermal contact resistance of r 2.5 x 104 m2 k/w. (a) what is the steady-state cooling load that must be maintained by the refrigerator under conditions for which the outer and inner surface temperatures are 25°c and -5°c, respectively? (b) for power saving purpose, which wall material should be increased/reduced in. thickness in order to reduce 50% of the cooling load found in part (a)? redesign the thickness of the proposed material. 177 w/m-k). adhesive interfaces between the q=575.93 w
Answers: 2
You know the right answer?
The composite wall of an oven consists of three materials, two of which are of known thermal conduct...
Questions
question
History, 16.10.2020 05:01
question
English, 16.10.2020 05:01
question
Mathematics, 16.10.2020 05:01
Questions on the website: 13722360