subject
Engineering, 31.12.2020 19:40 lexik4746

The utility companies often sell electric power at night at much lower prices since the demand for electric power is usually much higher during the day. The owner of a four-story Hotel would like to take advantage of this opportunity. The owner decides to design a pump piping system that delivers water from the lake to the large pool (or reservoir) located on the roof of the Hotel. The owner wants to fill the pool from sea water during the night when the electric power is cheap and to use the water during the day. Therefore, the owner decides to hire a mechanical engineer to design this piping pump system to deliver the water from the close lake to the reservoir on the roof of the building. As a hired mechanical engineer, you are supposed to design this piping pump system by selecting the desired pipe size, flow rate and all necessary fittings, and determine the horsepower of the pump required for such a delivery.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:20
Determine the damped natural frequencies and the steady state response of a decoupled damped forced two degrees of freedom system. 10ä1 + 2q1 20q1 10 cos t; 10q2 +4q2 + 40q2 10 cos t
Answers: 3
question
Engineering, 06.07.2019 03:20
Steam at a pressure of 100 kpa and a quality of 50% initially fills a rigid vessel having a volume of 0.5 m^3. the steam is then heated, causing the pressure in the vessel to rise to 150 kpa. determine: i. the mass of the steam in the vessel. ii. the temperature and quality of the steam after the heating process. ii the mass of the vapour, mg and liquid, m in the vessel after the heating process. if the steam in the vessel is now further heated, what would the pressure and temperature in the vessel be when all steam has turned into saturated vapour? b. sketch the processes in part (a) and part (b) on p-v and t-v diagrams, indicating clearly the temperatures, pressures and the paths. c. (0.59kg, 111.4°c, 73%, 0.4307kg, 0.1 593kg, 2.11 bar, 121.84°c)
Answers: 1
question
Engineering, 06.07.2019 03:20
An air-conditioning system consists of a heating section and an evaporative cooler. air enters the heating section at 10°c and 70 percent relative humidity at a rate of 30m^3/min, and it leaves the evaporative cooler at 20°c and 60 percent relatively humidity. if the air conditioning system operates at a total pressure of 98 kpa, determine (a) the temperature and relative humidity of the air when it leaves the heating section, (b) the rate of heat transfer in the heating section, and (c) the rate of water added to air in the evaporative cooler
Answers: 2
question
Engineering, 06.07.2019 03:30
State the stress optic law in two dimension and obtain an expression for the same.
Answers: 2
You know the right answer?
The utility companies often sell electric power at night at much lower prices since the demand for e...
Questions
question
Mathematics, 22.02.2021 14:00
question
Mathematics, 22.02.2021 14:00
question
French, 22.02.2021 14:00
Questions on the website: 13722367