subject
Engineering, 18.11.2020 17:30 aa985960

Hot air for a large-scale drying operation is to be produced by routing the air over a tube bank (in orthogonal direction, unmixed), while products of combustion are routed through the tubes. The surface area of the heat exchanger is A = 25 m^2, and for the proposed operating conditions, the manufacturer specifies an overall exchanger of U = 35 W/m^2 K. The air and the combustion gasses may each be assumed to have a specific heat of 1040 J/kgK. Consider conditions for which combustion gasses flowing at 1 kg/s enter the heat exchanger at 800 K, while air at 5 kg/s has an inlet temperature 300 K. Required:
a. What are the air and gas outlet temperatures?
b. After extended operation, deposits on the inner tube surfaces are expected to provide a fouling resistance of 0.004 m^2K/W. Should operation be suspended in order to clean the tubes. Assume that cleaning must be performed if the exchanger performance reduces by more than 10%?

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Burgers vector is generally parallel to the dislocation line. a)-true b)-false
Answers: 2
question
Engineering, 04.07.2019 18:20
Agas mixture consists of 8 kmol of h2 and 2 kmol of n2. determine the mass of each gas and the apparent gas constant of the mixture.
Answers: 3
question
Engineering, 04.07.2019 18:20
A3-mm-thick panel of aluminum alloy (k 177 w/m-k, c 875 j/kg-k and ? = 2770 kg/m) is finished on both sides with an epoxy coating that must be cured at or above t,-150°c for at least 5 min. the production line for the curing operation involves two steps: (1) heating in a large oven with air at ts,0-175°c and a convection coefficient of h, 40 w/m2. k, and (2) cooling in a large chamber with air at 25°c and a con- vection coefficient of he 10 w/m2.k. the heating portion of the process is conducted over a time interval te which exceeds the ime required to reach 150°c by 5 min (h = r + 300 s). the coating has an emissivity of ? = 0.8, and the temperatures of the oven and chamber walls are 175 and 25°c, respectively. if the panel is placed in the oven at an initial temperature of 25°c and removed from the chamber at a safe-to-touch tempera ture of 37°c, what is the total elapsed time for the two-step curing operation?
Answers: 3
question
Engineering, 04.07.2019 18:20
Along 8-cm diameter steam pipe whose external surface temperature is 900c connects two buildings. the pipe is exposed to ambient air at 70c with a wind speed of 50 km/hr blowing across the pipe. determine the heat loss from the pipe per unit length. (b) air at 500c enters a section of a rectangular duct (15 cm x 20 cm) at an average velocity of 7 m/s. if the walls of the duct are maintained at 100c. a) the length of the tube for an exit temperature of the air to be 40 0c. b)the rate of heat transfer from the air. c) the fan power needed to overcome the pressure drop in this section of the duct.
Answers: 1
You know the right answer?
Hot air for a large-scale drying operation is to be produced by routing the air over a tube bank (in...
Questions
question
Mathematics, 20.07.2019 09:00
Questions on the website: 13722360