Engineering, 02.11.2020 16:20 jetblackcap

Optimum Pipe Sizing is a common issue in process industries. A liquid is contained in a reactor vessel at 115 bar absolute pressure. It is transferred to a storage vessel through a 50 mm internal diameter commercial steel pipe. The storage vessel is nitrogen blanketed and pressure above the liquid surface is kept constant at 1500 N/sq. m gauge. The total run of pipe between the two vessels is 300 m. The miscellaneous losses due to entry and exit losses, fittings, valves, etc., amount to 1200 equivalent pipe diameters. The liquid level in the storage vessel is at an elevation 20 m below the level in the reactor. A turbine is fitted in the pipeline to recover the excess energy that is available, over that required to transfer the liquid from one vessel to the other. The properties of the fluid are: density 895 kg/Cu. m, viscosity 0.76 mNs/

sq. m Any available/assumed cost data can be used

Perform the following tasks:

Present the detailed analysis of the problem at hand, Develop the Objective function and constraint Models Solve the Problem using appropriate optimization technique Perform sensitivity analysis.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:20
Derive the correction factor formula for conical nozzle i=-(1+ cosa) and calculate the nozzle angle correction factor for a nozzle whose divergence hal-fangle is 13 (hint: assume that all the mass flow originates at the apex of the cone.
Answers: 3
question
Engineering, 04.07.2019 18:20
What is the heat treatment of metals? what is the benefit of it? why and how it's useful? answer in details, do not write by hand.
Answers: 3
question
Engineering, 04.07.2019 18:20
Along 8-cm diameter steam pipe whose external surface temperature is 900c connects two buildings. the pipe is exposed to ambient air at 70c with a wind speed of 50 km/hr blowing across the pipe. determine the heat loss from the pipe per unit length. (b) air at 500c enters a section of a rectangular duct (15 cm x 20 cm) at an average velocity of 7 m/s. if the walls of the duct are maintained at 100c. a) the length of the tube for an exit temperature of the air to be 40 0c. b)the rate of heat transfer from the air. c) the fan power needed to overcome the pressure drop in this section of the duct.
Answers: 1
question
Engineering, 04.07.2019 18:20
For a gate width of 2 m into the paper, determine the force required to hold the gate abc at its location.
Answers: 1
You know the right answer?
Optimum Pipe Sizing is a common issue in process industries. A liquid is contained in a reactor vess...
Questions
question
Mathematics, 30.08.2020 20:01
question
Social Studies, 30.08.2020 20:01
question
Mathematics, 30.08.2020 20:01
question
History, 30.08.2020 20:01
question
Mathematics, 30.08.2020 20:01
question
Chemistry, 30.08.2020 20:01
Questions on the website: 13722363