subject
Engineering, 21.10.2020 17:01 paytonxxburns05

Air with a volumetric flow rate of 15,000 ft3/min enters an air-handling unit at 35oF, 1 atm. The air-handling unit delivers air at 80oF, 1 atm to a duct system with three branches consisting of two 26-inch-diameter ducts and one 50-inch duct. The velocity in each 26-inch duct is 10 ft/s. Assuming ideal gas behavior for the air, determine at steady state (a) The mass flow rate of air entering the air-handling unit (in lbm/s) (b) The volumetric flow rate in each 26-inch duct (in ft3/min) (c) The velocity in the 50-inch duct (in ft/s)

ansver
Answers: 2

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Two flowing streams of argon gas are adiabatically mixed to form a single flow/stream. one stream is 1.5 kg/s at 400 kpa and 200 c while the second stream is 2kg/s at 500 kpa and 100 ? . it is stated that the exit state of the mixed single flow of argon gas is 150 c and 300 kpa. assuming there is no work output or input during the mixing process, does this process violate either the first or the second law or both? explain and state all your assumptions.
Answers: 1
question
Engineering, 04.07.2019 18:10
Consider a large isothermal enclosure that is maintained at a uniform temperature of 2000 k. calculate the emissive power of the radiation that emerges from a small aperture on the enclosure surface. what is the wavelength ? , below which 10% of the emission is concentrated? what is the wavelength ? 2 above which 10% of the emission is concentrated? determine the wavelength at which maximum spectral emissive power occurs. what is the irradiation incident on a small object placed inside the enclosure?
Answers: 2
question
Engineering, 04.07.2019 18:10
Condition monitoring is a major component of. (clo4) a)- predictive maintenance. b)-preventive maintenance c)-proactive maintenance d)-reactive maintenance.
Answers: 1
question
Engineering, 04.07.2019 18:20
Derive the correction factor formula for conical nozzle i=-(1+ cosa) and calculate the nozzle angle correction factor for a nozzle whose divergence hal-fangle is 13 (hint: assume that all the mass flow originates at the apex of the cone.
Answers: 3
You know the right answer?
Air with a volumetric flow rate of 15,000 ft3/min enters an air-handling unit at 35oF, 1 atm. The ai...
Questions
question
Mathematics, 20.02.2021 03:50
question
Mathematics, 20.02.2021 03:50
question
History, 20.02.2021 03:50
question
Mathematics, 20.02.2021 03:50
question
Mathematics, 20.02.2021 03:50
question
Mathematics, 20.02.2021 03:50
Questions on the website: 13722362