subject
Engineering, 16.10.2020 14:01 ptrlvn01

Cases of product are conveyed to automatic palletizers for palletizing. Depending on the particular product and carton dimensions, the palletizer has to be reprogrammed by an operator. Typically, 25 pallet loads are completed before reprogramming is needed. The reprogramming requires 4 minutes. The palletizer operates automatically for 40 minutes. The palletizer operator also must restock the machine with empty pallets; this can be done at any time during the last 10 minutes of the palletizer's automatic run time; restocking pallets requires 5 minutes. Travel time between palletizers, plus data entry in the computer system by the operator, requires 3 minutes. Required:
What is the maximum number of palletizers one operator can tend without creating idle time for the palletizer?

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
An ideal otto cycle with air as the working fluid has a compression ratio of 8. the minimum and maximum temperatures in the cycle are 300 k and 1340 k. use constant specific heats at room temperature to determine (a) the amount of heat transferred to the air during the heat- addition kj/kg, (b) the thermal efficiency, and (c) the thermal efficiency of a carnot cycle ope limits. process, in rating between the same temperature
Answers: 2
question
Engineering, 04.07.2019 18:10
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60Β°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
question
Engineering, 04.07.2019 18:20
Inadequate stores control is not an obstacle to effective work order system. (clo4) a)-true b)-false
Answers: 3
question
Engineering, 04.07.2019 18:20
Along 8-cm diameter steam pipe whose external surface temperature is 900c connects two buildings. the pipe is exposed to ambient air at 70c with a wind speed of 50 km/hr blowing across the pipe. determine the heat loss from the pipe per unit length. (b) air at 500c enters a section of a rectangular duct (15 cm x 20 cm) at an average velocity of 7 m/s. if the walls of the duct are maintained at 100c. a) the length of the tube for an exit temperature of the air to be 40 0c. b)the rate of heat transfer from the air. c) the fan power needed to overcome the pressure drop in this section of the duct.
Answers: 1
You know the right answer?
Cases of product are conveyed to automatic palletizers for palletizing. Depending on the particular...
Questions
question
Mathematics, 04.02.2020 06:43
question
Mathematics, 04.02.2020 06:43
question
Mathematics, 04.02.2020 06:43
Questions on the website: 13722367