Engineering, 16.10.2020 14:01 ravenl1001

Suppose an underground storage tank has been leaking for many years, contaminating a groundwater and causing a contaminant concentration directly beneath the site of 0.30 mg/L. The contamination is flowing at the rate of 0.5 ft/day toward a public drinking water well 1 mile away. The contaminant degrades with a rate constant of 1.94 x 10^-4 1/day. Draw a picture of the system. Estimate the steady-state pollutant concentration expected at the well. If the slope factor is 0.02 (mg/kg-day)^-1. Required:
Estimate the cancer risk for an adult male drinking the water for 10 years.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
For the closed feedwater heater below, feedwater enters state 3 at a pressure of 2000 psia and temperature of 420 °f at a rate of ix10 ibhr. the feedwat extracted steam enters state 1 at a pressure of 1000 psia and enthalpy of 1500 btu/lbm. the extracted er leaves at an enthalpy of 528.7 btu/lbm steam leaves as a saturated liquid. (16) a) determine the mass flow rate of the extraction steam used to heat the feedwater (10) b) determine the terminal temperature difference of the closed feedwater heater
Answers: 3
question
Engineering, 04.07.2019 19:10
Asteel wire of 2 mm diameter is fixed between two points located 2 m apart. the tensile force in the wire is 250n, if its density of steel is given by 7830 kg/m3 the fundamental frequency of vibration hz? ?
Answers: 3
question
Engineering, 04.07.2019 19:10
Aplate of dimensions 3 m x 3 m is placed 0.37 mm apart from a fixed plate. the plate requires a force of 2n to move at speed of 45 cm/s. evaluate the viscosity of the fluid in between the plates
Answers: 3
question
Engineering, 04.07.2019 19:20
Acommercial grade cubical freezer, 4 m on a side, has a composite wall consisting of an exterior sheet of 5.0-mm thick plain carbon steel (kst= 60.5 w/m k), an intermediate layer of 100-mm thick polyurethane insulation (kins 0.02 w/m k), and an inner sheet of 5.0- mm thick aluminium alloy (kal polyurethane insulation and both metallic sheets are each characterized by a thermal contact resistance of r 2.5 x 104 m2 k/w. (a) what is the steady-state cooling load that must be maintained by the refrigerator under conditions for which the outer and inner surface temperatures are 25°c and -5°c, respectively? (b) for power saving purpose, which wall material should be increased/reduced in. thickness in order to reduce 50% of the cooling load found in part (a)? redesign the thickness of the proposed material. 177 w/m-k). adhesive interfaces between the q=575.93 w
Answers: 2
You know the right answer?
Suppose an underground storage tank has been leaking for many years, contaminating a groundwater and...
Questions
question
Spanish, 04.09.2020 21:01
question
Mathematics, 04.09.2020 21:01
question
Mathematics, 04.09.2020 21:01
question
History, 04.09.2020 21:01
question
Biology, 04.09.2020 21:01
Questions on the website: 13722367