A lossless air spaced T-line having a characteristic impedance of 75 Ohms and 0.65 lamda in length is terminated in a load impedance of 75 ā€“ j90 ohm. Use the Smith Chart to find ā€¢ the input impedance of the load line combination
ā€¢ the reflection coefficient (magnitude and phase angle) at the load
ā€¢ the reflection coefficient (magnitude and phase angle) at the line input
ā€¢ the SWR of the load-line combination
ā€¢ the distance in wavelengths of the first voltage minimum away from the load
Clearly show all results and method on the smith chart.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
You are making beer. the first step is filling the glass carboy with the liquid wort. the internal diameter of the carboy is 15 in., and you wish to fill it up to a depth of 2 ft. if your wort is drawn from the kettle using a siphon process that flows at 3 gpm, how long will it take to fill?
Answers: 1
question
Engineering, 04.07.2019 18:10
Assuming compressible flow of air and that the measurements are done at flagstaff a pitot static tube that gives the difference of total and static pressure measures 0.35 m of mercury. what is the velocity of air? assume the temperature to be 300k. (submit your excel or matlab calculation sheet)
Answers: 1
question
Engineering, 04.07.2019 18:20
Athin walled concentric tube exchanger is used to cool engine oil from 160Ā°c to 60Ā°c with water that is available at 25Ā°c acting as a coolant. the oil and water flow rates are each at 2 kg/s, and the diameter of the inner tube is 0.5 m and the corresponding value of the overall heat transfer coefficient is 250 w/m2. oc. how long must the heat exchanger be to accomplish the desired cooling? cpwater=4.187 kj/kg-candcpengine el=2.035 kj/kgĀ·Ā°c, oil . 120]
Answers: 1
question
Engineering, 04.07.2019 18:20
Refrigerant-134a enters the compressor of a refrigerator as superheated vapor at 0.14 mpa and -10Ā°c at a rate of 0.05 ka/s and leaves at 0.8 mpa and 50Ā°c. the refrigerant is cooied in the condenser to 0.72 mpa and 26'c. it is then throttled to 0.15 mpa. sketch the t-s diagram for the system and evaluate: 6) the rate of heat removai from the refrigerated space (kw), it) the power input to the compressor (kw), ii) the isentropic efficiency of the compressor (%), and iv) the cop of the refrigerator.
Answers: 2
You know the right answer?
A lossless air spaced T-line having a characteristic impedance of 75 Ohms and 0.65 lamda in length i...
Questions
question
Social Studies, 22.12.2019 08:31
question
Biology, 22.12.2019 08:31
question
Mathematics, 22.12.2019 08:31
Questions on the website: 13722367