A single phase, 50-KVA, 2400-240-volt, 60 Hz distribution transformer has the following parameters: • Resistance of the 2400-volt winding Ri=0.75 ohm
Resistance of the 240-volt winding R=0.0075 ohm
Leakage reactance of the 2400-volt winding X:=1 ohm
Leakage reactance of the 240-volt winding X2=0.01 ohm
Core loss resistance on the 2400 side Rc=733.5 ohms
Magnetizing reactance on the 2400 side X=4890 ohms
a. Draw the equivalent circuit referred to the high voltage side and referred to the low- voltage side. Label the impedances numerically.
b. The transformer is used as a step-down transformer at the load end of a feeder having impedance of (0.5+j2.0) ohms. Determine the voltage V. at the ending end of the feeder when the transformer delivers rated load at rated secondary voltage and 0.8 laggin power factor. Neglect the "exciting current" l. of the transformer (this is the current into the parallel Rc/jXm combination), which is another way of saying that you should use what we called in class the "approximate circuit #2).

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
The thermal expansion or contraction of a given metal is a function of the f a)-density b)-initial temperature c)- temperature difference d)- linear coefficient of thermal expansion e)- final temperature f)- original length
Answers: 2
question
Engineering, 04.07.2019 18:10
A-mn has a cubic structure with a0 0.8931 nm and a density of 7.47 g/cm3. b-mn has a different cubic structure, with a0 0.6326 nm and a density of 7.26 g/cm3. the atomic weight of manganese is 54.938 g/mol and the atomic radius is 0.112 nm. determine the percent volume change that would occur if a-mn transforms to b-mn.
Answers: 2
question
Engineering, 04.07.2019 18:10
Atmospheric air has a temperature (dry bulb) of 80° f and a wet bulb temperature of 60° f when the barometric pressure is 14.696 psia. determine the specific humidity, grains/lb dry air. a. 11.4 c. 55.8 d. 22.5 b. 44.1
Answers: 1
question
Engineering, 04.07.2019 18:20
Air is compressed isentropically from an initial state of 300 k and 101 kpa to a final temperature of 1000 k. determine the final pressure using the following approaches: (a) approximate analysis (using properties at the average temperature) (b) exact analysis
Answers: 1
You know the right answer?
A single phase, 50-KVA, 2400-240-volt, 60 Hz distribution transformer has the following parameters:...
Questions
question
English, 26.01.2021 19:10
question
English, 26.01.2021 19:10
question
Mathematics, 26.01.2021 19:10
question
Mathematics, 26.01.2021 19:10
Questions on the website: 13722360