subject
Engineering, 15.10.2020 08:01 haza1873

The momentum equation for a control volume fixed in space is given by: /t∰d + ∯(⋅d)S=−∯(p−p[infinity])dS+∰d+visco us

Show how this equation would need to be modified if it were applied to each of the following (different) scenarios:

a. A control volume defined in a flow at steady state for which this no fluid is passing the boundaries.
b. A control volume defined in a flow at steady state for which gravitational forces and pressure forces can be neglected.
c. A control volume defined in a flow at steady state where the friction on a wall boundary can be neglected.
d. A control volume defined around a fluid in an open tank fitted with a pinhole at the bottom from which fluid leaks out from over time.
e. A control volume defined around a steady state flow that is only pressure driven.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Aloaded platform of total mass 500 kg is supported by a dashpot and by a set of springs of effective stiffness 72 kn/m. it is observed that when the platform is depressed through a distance x = 12.5 cm below its equilibrium position and then released without any initial velocity; it reaches its equilibrium position in the shortest possible time without overshoot. find the position and velocity of the loaded platform 0.10 sec. after its release. if a further load of 400 kg is added to the platform, find, i) the frequency of damped vibrations, and i) the amplitude of vibration after 2 complete oscillations, given that the initial amplitude is 15 cm.
Answers: 1
question
Engineering, 04.07.2019 18:10
Manometers are good examples of measuring instruments, nowadays they are not as common as before. a)-capacitive probe gauges b)-gravitational gauges deformation ) gauges d)-digital gauges
Answers: 1
question
Engineering, 04.07.2019 18:10
Water at the rate of 1 kg/s is forced through a tube with a 2.5 cm inner diameter. the inlet water temperature is 15°c, and the outlet water temperature is 50°c. the tube wall temperature is 14°c higher than the local water temperature all along the length of the tube. what is the length of the tube?
Answers: 3
question
Engineering, 04.07.2019 18:20
Most leaks in reciprocating air compressors can be detected and minimized by: (clo4) a)-detecting leakage areas using ultrasonic acoustic detector. b)-tightening joints and connections c)-replacing faulty equipment d)-all of the given options
Answers: 2
You know the right answer?
The momentum equation for a control volume fixed in space is given by: /t∰d + ∯(⋅d)S=−∯(p−p[infinit...
Questions
question
Geography, 20.02.2020 23:11
Questions on the website: 13722363