The problem of interest is to understand how both temperature and the rate of heat loss in the contents of the tank will vary as a consequence of unplanned and possibly random changes in Tin, and operator-introduced actions in the rate of heat addition Q. The rate of heat loss is a function of volume V and tank temperature T, as defined by the equation, QL= αVT^2

α is a constant-valued coefficient. You may assume the following:

a. Consider the scenario where both inlet and outlet volumetric flow rates are equal, i. e., q_in = q_out = q.
b. Densities and heat capacities are constant and equal for all streams: pressure is constant through the process.
c. The system is well-mixed: furthermore, the rate of shaft work is negligible.

Please perform the following:

1. Use the appropriate conservation and accounting statements to obtain the system of equations that describe the dynamics of the problem. Clearly state your assumptions, system and system boundaries, and simplification steps required to obtain the appropriate model equations.
2. Represent the system of equations from part a) in lumped parameter state-space form, and indicate the inputs (manipulated and disturbances), outputs, and states.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Assuming compressible flow of air and that the measurements are done at flagstaff a pitot static tube that gives the difference of total and static pressure measures 0.35 m of mercury. what is the velocity of air? assume the temperature to be 300k. (submit your excel or matlab calculation sheet)
Answers: 1
question
Engineering, 04.07.2019 18:20
Air flows over a heated plate àt a velocity of 50m/s. the local skin factor coefficient at a point on a plate is 0.004. estimate the local heat transfer coefficient at this point.the following property data for air are given: density = 0.88kg/m3 , viscosity 2.286 x 10 ^-5 kgm/s , k = 0.035w/mk ,cp = 1.001kj/kgk. use colburn reynolds analogy.
Answers: 1
question
Engineering, 04.07.2019 19:10
When subject to a steady load (within elastic range) over a long period of time, what is the major difference in material behavoir between steel and plastic?
Answers: 2
question
Engineering, 04.07.2019 19:20
Determine the time of the day and month of the year at which the peak sensible cooling load occurs for a top floor, north-eastern corner room of an office building in durban for the following conditions: floor area: 8 x 8 x 3 m east and north walls: 115 mm face brick (outside), 20 mm air space, 115 mm ordinary brick (inside) with 15 mm plaster roof construction: suspended plasterboard ceiling, 450 mm air space, 150 mm concrete, 75mm screed, waterproofing no heat transfer across other surfaces window area 3x 1,5 m high in north wall only. ordinary glass with venetian blinds. lights and occupants : from 07: 00 to 18: 00 average light density: 25 w/m2 number of occupants : 5 seated, light office work room temperature 24°c
Answers: 3
You know the right answer?
The problem of interest is to understand how both temperature and the rate of heat loss in the conte...
Questions
question
Mathematics, 23.02.2021 18:00
question
Mathematics, 23.02.2021 18:00
question
Mathematics, 23.02.2021 18:00
question
Mathematics, 23.02.2021 18:00
question
English, 23.02.2021 18:00
question
History, 23.02.2021 18:00
Questions on the website: 13722361