subject
Engineering, 20.09.2020 14:01 abbygriffin2009

The steam requirements of a manufacturing facility are being met by a boiler whose rated heat input is 5.5 x 106 Btu/h. The combustion efficiency of the boiler is measured to be 0.65. After tuning up the boiler, the combustion efficiency rises to 0.75. The boiler operates 4000 hours a year intermittently. Take the unit cost of energy to be $4.35/106 Btu. Assuming the same heat output for before and after the tunning:.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Two flowing streams of argon gas are adiabatically mixed to form a single flow/stream. one stream is 1.5 kg/s at 400 kpa and 200 c while the second stream is 2kg/s at 500 kpa and 100 ? . it is stated that the exit state of the mixed single flow of argon gas is 150 c and 300 kpa. assuming there is no work output or input during the mixing process, does this process violate either the first or the second law or both? explain and state all your assumptions.
Answers: 1
question
Engineering, 04.07.2019 18:20
Inadequate stores control is not an obstacle to effective work order system. (clo4) a)-true b)-false
Answers: 3
question
Engineering, 04.07.2019 18:20
Steam enters a converging nozzle at 3.0 mpa and 500°c with a at 1.8 mpa. for a nozzle exit area of 32 cm2, determine the exit velocity, mass flow rate, and exit mach number if the nozzle: negligible velocity, and it exits (a) is isentropic (b) has an efficiency of 94 percent
Answers: 2
question
Engineering, 04.07.2019 18:20
Along 8-cm diameter steam pipe whose external surface temperature is 900c connects two buildings. the pipe is exposed to ambient air at 70c with a wind speed of 50 km/hr blowing across the pipe. determine the heat loss from the pipe per unit length. (b) air at 500c enters a section of a rectangular duct (15 cm x 20 cm) at an average velocity of 7 m/s. if the walls of the duct are maintained at 100c. a) the length of the tube for an exit temperature of the air to be 40 0c. b)the rate of heat transfer from the air. c) the fan power needed to overcome the pressure drop in this section of the duct.
Answers: 1
You know the right answer?
The steam requirements of a manufacturing facility are being met by a boiler whose rated heat input...
Questions
question
Mathematics, 18.09.2020 08:01
question
Mathematics, 18.09.2020 08:01
question
History, 18.09.2020 08:01
question
Mathematics, 18.09.2020 08:01
question
Mathematics, 18.09.2020 08:01
question
Mathematics, 18.09.2020 08:01
question
Mathematics, 18.09.2020 08:01
question
Mathematics, 18.09.2020 08:01
question
Mathematics, 18.09.2020 08:01
question
Mathematics, 18.09.2020 08:01
question
Mathematics, 18.09.2020 08:01
question
Biology, 18.09.2020 08:01
question
Mathematics, 18.09.2020 08:01
question
Mathematics, 18.09.2020 08:01
question
Mathematics, 18.09.2020 08:01
question
Mathematics, 18.09.2020 08:01
question
Mathematics, 18.09.2020 08:01
question
Social Studies, 18.09.2020 08:01
question
Mathematics, 18.09.2020 08:01
question
History, 18.09.2020 08:01
Questions on the website: 13722363