subject
Engineering, 13.08.2020 04:01 kornut7316

An air-conditioner which uses R-134a operates on the ideal vapor compression refrigeration cycle with a given compressor efficiency. --Given Values--
Evaporator Temperature: T1 (C) = 9
Condenser Temperature: T3 (C) = 39
Mass flow rate of refrigerant: mdot (kg/s) = 0.027
Compressor Efficiency: nc (%) = 90

a) Determine the specific enthalpy (kJ/kg) at the compressor inlet.
Your Answer =
b) Determine the specific entropy (kJ/kg-K) at the compressor inlet
Your Answer =
c) Determine the specific enthalpy (kJ/kg) at the compressor exit
Your Answer =
d) Determine the specific enthalpy (kJ/kg) at the condenser exit.
Your Answer =
e) Determine the specific enthalpy (kJ/kg) at the evaporator inlet.
Your Answer =
f) Determine the coefficient of performance for the system.
Your Answer =
g) Determine the cooling capacity (kW) of the system.
Your Answer =
h) Determine the power input (kW)to the compressor.
Your Answer =

ansver
Answers: 3

Another question on Engineering

question
Engineering, 03.07.2019 15:10
If you were designing a bumper for a car, would you prefer it to exhibit elastic or plastic deformation? why? consider the functions of a bumper in both a minor "fender-bender" and a major collision.
Answers: 1
question
Engineering, 03.07.2019 15:10
Two flowing streams of argon gas are adiabatically mixed to form a single flow/stream. one stream is 1.5 kg/s at 400 kpa and 200 c while the second stream is 2kg/s at 500 kpa and 100 ? . it is stated that the exit state of the mixed single flow of argon gas is 150 c and 300 kpa. assuming there is no work output or input during the mixing process, does this process violate either the first or the second law or both? explain and state all your assumptions.
Answers: 1
question
Engineering, 04.07.2019 18:10
Which of the following components of a pid controlled accumulates the error over time and responds to system error after the error has been accumulated? a)- proportional b)- derivative c)- integral d)- on/off.
Answers: 2
question
Engineering, 04.07.2019 18:20
Vibration monitoring this technique uses the noise or vibration created by mechanical equipment and in seme cases by plant systems to detemine their actual condtion. a)- true b)- false