A thermocouple junction with a diffuse and gray surface is placed in a large environment of temperature at T. The junction is used to measure the temperature of a moving fluid surrounding the surface. The heat transfer coefficient is h. The total hemispherical irradiation from the environment incident on the small surface is. The total hemispherical emissivity of the surface is 0.95. Determine the following: A) What is the radiation energy incident on the surface per unit time (q_irra)?
B) What is the total hemispherical absorptivity alpha?
C) What is the radiation energy absorbed by the surface per unit time q_abs?
D) If after steady state, the temperature of the junction senses a temperature of 320 K, what is the total hemispherical emitted power E from the junction surface?
E) What is the radiation energy emitted from the junction surface per unit time q_emit?
F) Apply energy balance to the junction after steady state. Neglect the contribution from the thermocouple wires. Calculate the temperature of the fluid. What is the major reason that the temperature of the fluid cannot be accurately measured by the thermocouple junction?

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
The higher the astm grain size number, the finer the gran is. a)-true b)-false
Answers: 2
question
Engineering, 04.07.2019 18:10
Hydraulic fluid with a sg. of 0.78 is flowing through a 1.5 in. i.d. pipe at 58 gal/min. the fluid has an absolute viscosity of 11.8 x 105 lbf-sec/ft2. is the flow laminar, turbulent or within the critical range? give both a numerical reynolds number and a term answer.
Answers: 3
question
Engineering, 04.07.2019 18:10
Journeyman training is usually related (clo2) a)-to specific tasks b)-to cost analysis of maintenance task c)-to control process to ensure quality d)-to installation of machinery
Answers: 2
question
Engineering, 04.07.2019 19:10
An external consultant recommends that a plant installs a bank of capacitors for power factor correction. this will reduce the peak electrical demand charges by an average of 93 kw every month. the plant current pays $13 per kw in peak demand charges. the capacitor bank will include 223 kw of fixed capacitors, and 183 of variable capacitors. the fixed capacitors cost $59 per kw, and the variable capacitors will cost $65 per kw. the consultant charges 21% of the equipment costs to install the capacitors. because this project will reduce the demand for the electric utility, they are prepared to provide a one-time rebate of $42 per kw of reduced demand. what is the simple payback period for this project (in years)?
Answers: 2