subject
Engineering, 31.07.2020 20:01 MoneyMike42

A single phase, 2000: 230 V, 50 Hz transformer is connected to an inductive load with an impedance, Zload , of 10 ∠ 30o Ω. The resistance, Rp, and inductance, Lp, on the primary side are 15 Ω and 26 mH , respectively. The core losses are represented by a resistance of 450 Ω and the magnetising reactance is 50 Ω. The secondary side resistance and inductance are 0.2 Ω and 0.1 mH. Approximate Equivalent Circuit:

Show your working clearly.
(a) Sketch the Approximate equivalent transformer for the diagram and Calculate the relevant parameters and indicate these on your sketch.
(b) Use the approximate equivalent circuit to calculate the primary current.
(c) Calculate the voltage across the load referred to the secondary.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 03.07.2019 14:10
The y form of iron is known as: a) ferrite b) cementite c) perlite d) austenite
Answers: 3
question
Engineering, 04.07.2019 18:10
Manometers are good examples of measuring instruments, nowadays they are not as common as before. a)-capacitive probe gauges b)-gravitational gauges deformation ) gauges d)-digital gauges
Answers: 1
question
Engineering, 04.07.2019 18:20
Asolid cylinder is concentric with a straight pipe. the cylinder is 0.5 m long and has an outside diameter of 8 cm. the pipe has an inside diameter of 8.5 cm. the annulus between the cylinder ad the pipe contains stationary oil. the oil has a specific gravity of 0.92 and a kinematic viscosity of 5.57 x 10-4 m2/s. most nearly, what is the force needed to move the cylinder along the pipe at a constant velocity of 1 m/s?
Answers: 3
question
Engineering, 04.07.2019 18:20
Along 8-cm diameter steam pipe whose external surface temperature is 900c connects two buildings. the pipe is exposed to ambient air at 70c with a wind speed of 50 km/hr blowing across the pipe. determine the heat loss from the pipe per unit length. (b) air at 500c enters a section of a rectangular duct (15 cm x 20 cm) at an average velocity of 7 m/s. if the walls of the duct are maintained at 100c. a) the length of the tube for an exit temperature of the air to be 40 0c. b)the rate of heat transfer from the air. c) the fan power needed to overcome the pressure drop in this section of the duct.
Answers: 1
You know the right answer?
A single phase, 2000: 230 V, 50 Hz transformer is connected to an inductive load with an impedance,...
Questions
question
English, 16.10.2019 00:00
question
Mathematics, 16.10.2019 00:00
question
Business, 16.10.2019 00:00
question
Mathematics, 16.10.2019 00:00
Questions on the website: 13722363