1. Explain why your measurement of the line in Part A might not be identical to the measurements taken by your lab mates Assuming all the measurements were taken correctly, what is the maximum number of digits that should differ between your measurement and those from your lab mates? 2. When measuring a small volume, such as the volume of a small test tube, should you use a 10 mL, 25 ml, or 50 ml graduated cylinder to obtain the most precise measurement? Explain your choice.
3. In Part B, did all of your mass measurements have the same number of digits after the decimal place? If not, Is there a difference in the amount of Information provided by the measurements? What does this tell you about the ability of the electronic balance to measure the masses of objects of significantly different sizes? Justify your answers.
4. Did your data from Part C suggest that filling a 125 mL Erlenmeyer flask to the indicated line is a reliable way to votain 125 mL of lould2 When you need to make a volume measurement in the lab, which is the best choice of instrument: a graduated cylinder, beaker, or Erlenmeyer flask? Explain your answer.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Which of the following ziegler nichols tuning methods the response of the controller to a step input should exhibit an s-shaped curve? a)-open loop mode b)-closed loop mode c)-both modes (open & closed) d)-none of the modes (open & closed)
Answers: 3
question
Engineering, 04.07.2019 18:10
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
question
Engineering, 04.07.2019 18:10
Aturning operation is performed with following conditions: rake angle of 12°, a feed of 0.35 mm/rev, and a depth of cut of 1.1 mm. the work piece is aluminum alloy 6061 with t6 heat treatment (a16061-t6). the resultant chip thickness was measured to be 1.0 mm. estimate the cutting force, fc. use shear stress of 207 mpa and coefficient of friction on the tool face of 0.6.
Answers: 1
question
Engineering, 04.07.2019 18:20
Amixture of slurry and mud is to be pumped through a horizontal pipe of diameter 500 mm. the fluid behaves as a bingham plastic with a yield stress of 30 pa and viscosity 0.04 pa.s. describe the effects of the shear stress through a transverse section of the pipe by plotting the variation in shear stress and velocity profile: (i) just before the slurry starts to move (ii) as the slurry flows when the pressure gradient is double that in part (i)
Answers: 3
You know the right answer?
1. Explain why your measurement of the line in Part A might not be identical to the measurements tak...