subject
Engineering, 14.07.2020 23:01 zahrast14

A supply of 24V is applied across a resistance combination consisting of the following: three resistors of 6Ω, 12Ω, and 36Ω connected in parallel and a fourth resistor of 16.4 Ω connected in series with the parallel group. Find the total circuit current

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:20
A3-mm-thick panel of aluminum alloy (k 177 w/m-k, c 875 j/kg-k and ? = 2770 kg/m) is finished on both sides with an epoxy coating that must be cured at or above t,-150°c for at least 5 min. the production line for the curing operation involves two steps: (1) heating in a large oven with air at ts,0-175°c and a convection coefficient of h, 40 w/m2. k, and (2) cooling in a large chamber with air at 25°c and a con- vection coefficient of he 10 w/m2.k. the heating portion of the process is conducted over a time interval te which exceeds the ime required to reach 150°c by 5 min (h = r + 300 s). the coating has an emissivity of ? = 0.8, and the temperatures of the oven and chamber walls are 175 and 25°c, respectively. if the panel is placed in the oven at an initial temperature of 25°c and removed from the chamber at a safe-to-touch tempera ture of 37°c, what is the total elapsed time for the two-step curing operation?
Answers: 3
question
Engineering, 04.07.2019 19:10
An external consultant recommends that a plant installs a bank of capacitors for power factor correction. this will reduce the peak electrical demand charges by an average of 93 kw every month. the plant current pays $13 per kw in peak demand charges. the capacitor bank will include 223 kw of fixed capacitors, and 183 of variable capacitors. the fixed capacitors cost $59 per kw, and the variable capacitors will cost $65 per kw. the consultant charges 21% of the equipment costs to install the capacitors. because this project will reduce the demand for the electric utility, they are prepared to provide a one-time rebate of $42 per kw of reduced demand. what is the simple payback period for this project (in years)?
Answers: 2
question
Engineering, 06.07.2019 03:20
Acountershaft is supported by two tapered roller bearings using indirect mounting. the radial bearing loads are 1120 lb for the left-hand bearing and 2190 lb for the right-hand bearing. the shaft rotates at 400 rpm and is to have an l10 life of 40,000 hours and an application factor of 1.4. assume ka2k 15, and find the required radial rating of each bearing
Answers: 3
question
Engineering, 06.07.2019 03:30
State the stress optic law in two dimension and obtain an expression for the same.
Answers: 2
You know the right answer?
A supply of 24V is applied across a resistance combination consisting of the following: three resist...
Questions
Questions on the website: 13722362