subject
Engineering, 05.07.2020 14:01 marley462847

1. How many PWM generator blocks are there in LM3S1968? What are they? 2. How many independent PWM outputs can be generated on an LM3S1968? 3. List at least two applications for PWM. 4. What does NVIC in a timer stand for? Explain its significance. 5. Where does the counter/timer derive its time period from? 6. Draw the waveforms (square wave) with duty cycles (on) 25%, 50%, 75%.One of the purpose of the lab is to generate a PWM signal in one of the ports using systick timer. a. Given a signal with 1 KHz, find out the time period of each cycle. Find out the time span of the high signal and the low signal given 10%, 20%, 30% and 90% duty cycles. b. We would like to generate a signal with a certain frequency (ex. 100 Hz, 1 KHz, etc.) and certain duty cycle (10%, 20%, etc.), find out the values we need to load into the timer register? Given that the XTAL = 8 MHz.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Apiston-cylinder with a volume of 0.25 m3 holds 1 kg of air (r 0.287 k/kgk) at a temperature of 100 c. heat transfer to the cylinder causes an isothermal expansion of the piston until the volume triples. how much heat is added to the piston-cylinder?
Answers: 3
question
Engineering, 04.07.2019 03:10
What precautions should you take to prevent injuries when dealing with heavy loads?
Answers: 1
question
Engineering, 04.07.2019 18:10
Air is to be cooled in the evaporator section of a refrigerator by passing it over a bank of 0.8-cm-outer-diameter and 0.4-m-long tubes inside which the refrigerant is evaporating at -20°c. air approaches the tube bank in the normal direction at 0°c and 1 atm with a mean velocity of 4 m/s. the tubes are arranged in-line with longitudinal and transverse pitches of sl- st 1.5 cm. there are 30 rows in the flow direction with 15 tubes in each row. determine (a) the refrigeration capacity of this system and (b) pressure drop across the tube bank. evaluate the air properties at an assumed mean temperature of -5°c and 1 atm. is this a good assumption?
Answers: 1
question
Engineering, 04.07.2019 18:10
Apipe with an outside diameter of 15 cm is exposed to an ambient air and surrounding temperature of -20°c. the pipe has an outer surface temperature of 65°c and an emissivity of 0.85. if the rate of heat loss from the pipe surface is 0.95 kw per meter of length, the external convective heat transfer coefficient (h) is: (a) 12.5 w/m"k (b) 18.6 w/mk (c) 23.7 w/mk (d) 27.9 w/mk (e) 33.5 w/mk
Answers: 1