subject
Engineering, 30.05.2020 18:02 kayla942783

You are required to design a heating oven for sterilizing equipment. The oven is heated by side
heater imbedded at the mid-plan of a wall of 20 cm thick. The wall is completely insulated from the air side. The material of the oven walls has k = 10 W/m K and the thickness of each wall other than that mentioned is 10 cm. The top and the bottom sides of the oven are completely insulated. The amount of heat lost from the walls should not exceed 5% of the input power to the

heater which is 2kW. In order to enhance the heat transfer from the wall where the heater is fitted
to the oven space, it is proposed to attach a number of either longitudinal or transverse fins to

this wall. The dimensions of each one of these fins as follows; its length is 15 cm and thickness is 3mm. The fin material is aluminum with k = 150 W/m K.
The oven is cubical in shape with side length 75 cm. If the inside temperature of air inside the
oven should be 75°C and the ambient temperature of the air outside the oven varies from 25°C to

40 °C. All the heat generated by the heater is transferred normal to its wall. Assume an average
fin temperature to calculate the heat transfer coefficient from fins to the oven space. After then
use this value of h to calculate the heat transfer from single fin and then find the number of fins
required to transfer the heat, assuming adiabatic tip fin, bearing in mind that heat is also
transferred from bare area of the wall where the fins are attached.
Explain which type of fins you recommend (longitudinal or transverse fins).
It is required also to select suitable insulating material used for this application and to calculate the
thickness of this material to suit the given condition of heat loss.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:20
Most leaks in reciprocating air compressors can be detected and minimized by: (clo4) a)-detecting leakage areas using ultrasonic acoustic detector. b)-tightening joints and connections c)-replacing faulty equipment d)-all of the given options
Answers: 2
question
Engineering, 04.07.2019 18:20
Steam enters a converging nozzle at 3.0 mpa and 500°c with a at 1.8 mpa. for a nozzle exit area of 32 cm2, determine the exit velocity, mass flow rate, and exit mach number if the nozzle: negligible velocity, and it exits (a) is isentropic (b) has an efficiency of 94 percent
Answers: 2
question
Engineering, 04.07.2019 19:20
Afan that can provide air speeds up to 60 m/s is to be used in a low-speed wind tunnel with atmospheric air at 35 c. if one wishes to use the wind tunnel to study flat-plate boundary layer behavior up to reynolds numbes of re 10, what is the minimum plate length that should be used? at what distance from the leading edge would transition occur if the critical reynolds nurnber were rer,e = 5 × 105?
Answers: 2
question
Engineering, 05.07.2019 19:10
Tech a says never use a water hose to clean up dust after a repair. tech b says never use a floor scrubber to clean up dust after repairs. who is correct?
Answers: 1
You know the right answer?
You are required to design a heating oven for sterilizing equipment. The oven is heated by side
Questions
question
Mathematics, 30.01.2021 06:20
question
Mathematics, 30.01.2021 06:20
question
Physics, 30.01.2021 06:20
question
History, 30.01.2021 06:20
question
Physics, 30.01.2021 06:20
question
Physics, 30.01.2021 06:20
question
Computers and Technology, 30.01.2021 06:20
Questions on the website: 13722362