subject
Engineering, 28.05.2020 01:06 aliami0306oyaj0n

A 460-V 60-Hz four-pole Y-connected induction motoris rated at 25 hp(note: this is the nominal output power at the nominal speed (or nominal slip).The equivalent circuit parameters areR1= 0.15 R2= 0.154 XM= 20 X1= 0.852 X2= 1.066 PF&W= 400 WPmisc= 150 WPcore= 400 WFor a slip of 0.02, find(Importantnote: this 2% slip mayor may notbe the nominal slip of the motoras it is not explicitly stated. Hence, the output power associated with this slip maybe different than the given nominal output power (i. e. 25 hp)).(a)The line current IL(b)The stator power factor (c)The rotor power factor (d)The rotor frequency (e)The stator copper losses SCLP(f)The air-gap power PAG(g)The power converted from electrical to mechanical form Pconv(h)The induced torque ind(i)The load torque load(j)The overall machine efficiency (k)The motor speed in revolutions per minute and radians per second(l)What is the starting line current of this motor?(Hint: starting slip is one, now redraw your circuit and solve it for the starting current)(m) What is the slip at the pullout torque? What is the pullout torque of this motor?

ansver
Answers: 1

Another question on Engineering

question
Engineering, 03.07.2019 23:20
Two technicians are discussing the intake air temperature (iat) sensor. technician a says that the computer uses the iat sensor as a backup to the engine coolant temperature (ect) sensor. technician b says that the powertrain control module (pcm) will subtract the calculated amount of fuel if the air measures hot. who is correct
Answers: 3
question
Engineering, 04.07.2019 18:10
Which of the following controllers anticipates the future from the slope of errors over time? a)-proportional b)-on/off c)-integral d)-derivative.
Answers: 2
question
Engineering, 04.07.2019 18:10
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
question
Engineering, 04.07.2019 18:20
The characteristic roots of a dynamic system are: 1.7920 1.8160 i, -1.7920 1.8160 i, -0.4160 what is the order of this system? what are the settling time and damping ratio of the system?
Answers: 3
You know the right answer?
A 460-V 60-Hz four-pole Y-connected induction motoris rated at 25 hp(note: this is the nominal outpu...
Questions
question
Mathematics, 01.04.2021 06:30
question
English, 01.04.2021 06:30
question
Mathematics, 01.04.2021 06:30
question
Mathematics, 01.04.2021 06:30
question
Mathematics, 01.04.2021 06:30
question
Mathematics, 01.04.2021 06:30
Questions on the website: 13722367