subject
Engineering, 05.05.2020 00:30 mamaKelly1671

G A data path is the path by which data flows in a system. In this lab, you will implement a simple data path with a register file, ALU, and user inputs. Each processor contains a register file that holds the registers used in program execution. Registers are fast access local variables that can change after every instruction. In this lab, you will be building a register file that contains four, 4-bit registers. Each of the four registers has an address (0b00 -> 0b11) and stores a 4-bit value. The value saved to a destination register (write register) will be chosen from one of two sources, the keypad user input, or the output of the ALU. The ALU in this system is a 4-bit bitwise right rotation (right circular shift) circuit that takes two of the register values as inputs (read registers). You may not use the MML library ALU and should instead build one out of muxes or logic gates. From the user interface, the user will select the data source (source select) and the addresses of the read and write registers.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Steel is coated with a thin layer of ceramic to protect against corrosion. what do you expect to happen to the coating when the temperature of the steel is increased significantly? explain.
Answers: 1
question
Engineering, 04.07.2019 18:20
A3-mm-thick panel of aluminum alloy (k 177 w/m-k, c 875 j/kg-k and ? = 2770 kg/m) is finished on both sides with an epoxy coating that must be cured at or above t,-150°c for at least 5 min. the production line for the curing operation involves two steps: (1) heating in a large oven with air at ts,0-175°c and a convection coefficient of h, 40 w/m2. k, and (2) cooling in a large chamber with air at 25°c and a con- vection coefficient of he 10 w/m2.k. the heating portion of the process is conducted over a time interval te which exceeds the ime required to reach 150°c by 5 min (h = r + 300 s). the coating has an emissivity of ? = 0.8, and the temperatures of the oven and chamber walls are 175 and 25°c, respectively. if the panel is placed in the oven at an initial temperature of 25°c and removed from the chamber at a safe-to-touch tempera ture of 37°c, what is the total elapsed time for the two-step curing operation?
Answers: 3
question
Engineering, 04.07.2019 19:10
The sum of the normal stresses does not change as the stress state rotates through an angle. a)-trune b)- false
Answers: 2
question
Engineering, 04.07.2019 19:10
Agas is compressed from vi 0.3 m, p 1 bar to of v2 0.1 m3, p2--3 bar. pressure and volume are related linearly during the process. for the gas, find the work, in kj.
Answers: 2
You know the right answer?
G A data path is the path by which data flows in a system. In this lab, you will implement a simple...
Questions
question
Mathematics, 23.04.2020 04:27
question
Mathematics, 23.04.2020 04:27
question
English, 23.04.2020 04:27
question
History, 23.04.2020 04:27
Questions on the website: 13722362