subject
Engineering, 05.05.2020 05:12 emmamanny

The flow and mixing patterns in this system are studied by dissolving 1500 g of a salt (S) in the first tank, and then starting the 40 L/s flow through the system. Each tank outlet stream is monitored with an on-line thermal conductivity detector calibrated to provide instantaneous readings of salt concentration. The data are plotted versus time, and the results are compared with the plots that would be expected if the tanks are all perfectly mixed. Your job is to generate the latter plots.

a) assuming that pure water is fed to the first tank and that each tank is perfectly mixed (so that the salt concentration in a tank is uniform and equal to the concentration in the outlet stream from that tank), write salt balances on each of the three tanks, convert them to expressions for dCS1 /dt, dCS2 / dt, and dCS3 / dt, and provide appropriate initial conditions.

b) without doing any calculations, on a single graph sketch the forms of the plots of CS1 versus t, CS2 versus t, and CS3 versus t you would expect to obtain. Briefly explain your reasoning.

c) Use a differential equation-solving program to solve the three equations, proceeding to a time at which CS3 has fallen below 0.01 g/L, and plot the results.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Give heat transfer applications for the following, (i) gas turbines (propulsion) ) gas turbines (power generation). (iii) steam turbines. (iv) combined heat and power (chp). (v) automotive engines
Answers: 1
question
Engineering, 04.07.2019 18:10
For the closed feedwater heater below, feedwater enters state 3 at a pressure of 2000 psia and temperature of 420 °f at a rate of ix10 ibhr. the feedwat extracted steam enters state 1 at a pressure of 1000 psia and enthalpy of 1500 btu/lbm. the extracted er leaves at an enthalpy of 528.7 btu/lbm steam leaves as a saturated liquid. (16) a) determine the mass flow rate of the extraction steam used to heat the feedwater (10) b) determine the terminal temperature difference of the closed feedwater heater
Answers: 3
question
Engineering, 04.07.2019 18:10
Water in a partially filled large tank is to be supplied to the roof top, which is 8 m above the water level in the tank, through a 2.2-cm-internal-diameter pipe by maintaining a constant air pressure of 300 kpa (gage) in the tank. if the head loss in the piping is 2 m of water, determine the discharge rate of the supply of water to the roof top in liters per second.
Answers: 3
question
Engineering, 04.07.2019 18:10
Which from the following instrument is commonly used to detect the high pitch butzing sound in bearings? [clo4] a)-digital ultrasonic meter b)-infrared camera c)-spectroscopic d)-vibrometer
Answers: 2
You know the right answer?
The flow and mixing patterns in this system are studied by dissolving 1500 g of a salt (S) in the fi...
Questions
question
Biology, 18.03.2021 01:10
question
Mathematics, 18.03.2021 01:10
question
Mathematics, 18.03.2021 01:10
question
Chemistry, 18.03.2021 01:10
question
Mathematics, 18.03.2021 01:10
Questions on the website: 13722360