subject
Engineering, 06.05.2020 03:28 brownvester44

As you recall, the Logic Schematic for Lab2&3 (‘Smart ECC Transportation ‘Bus’ with Robotic Arm: 4-Bit Microcomputer) was very complex and difficult because we used Logic Gates. How would an Arduino UNO Board using an 8-Bit Microcontroller improve or simplify the design and testing? Hint: Mention every experience you had in the Lab2&3 and Imagine if you used Arduino instead.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Apump is used to circulate hot water in a home heating system. water enters the well-insulated pump operating at steady state at a rate of 0.42 gal/min. the inlet pressure and temperature are 14.7 lbf/in.2, and 180°f, respectively; at the exit the pressure is 60 lbf/in.2 the pump requires 1/15 hp of power input. water can be modeled as an incompressible substance with constant density of 60.58 lb/ft3 and constant specific heat of 1 btu/lb or. neglecting kinetic and potential energy effects, determine the temperature change, in °r, as the water flows through the pump.
Answers: 1
question
Engineering, 04.07.2019 18:10
Manometers are good examples of measuring instruments, nowadays they are not as common as before. a)-capacitive probe gauges b)-gravitational gauges deformation ) gauges d)-digital gauges
Answers: 1
question
Engineering, 04.07.2019 18:10
Ifa component is made of two or more materials with different modulus of elasticity (e), it is called a composite member and we calculate the factor·n". mention the formula for calculating n". also, ifn> 1, explain what will happen to the 1. transformed.gi) ifn 1, what will happen to the material when transformed material when
Answers: 1
question
Engineering, 04.07.2019 18:20
Athin walled concentric tube exchanger is used to cool engine oil from 160°c to 60°c with water that is available at 25°c acting as a coolant. the oil and water flow rates are each at 2 kg/s, and the diameter of the inner tube is 0.5 m and the corresponding value of the overall heat transfer coefficient is 250 w/m2. oc. how long must the heat exchanger be to accomplish the desired cooling? cpwater=4.187 kj/kg-candcpengine el=2.035 kj/kg·°c, oil . 120]
Answers: 1
You know the right answer?
As you recall, the Logic Schematic for Lab2&3 (‘Smart ECC Transportation ‘Bus’ with Robotic Arm:...
Questions
question
Mathematics, 21.05.2021 21:00
question
History, 21.05.2021 21:00
question
Mathematics, 21.05.2021 21:00
question
Mathematics, 21.05.2021 21:00
question
Mathematics, 21.05.2021 21:00
question
Mathematics, 21.05.2021 21:00
question
Mathematics, 21.05.2021 21:00
Questions on the website: 13722367