subject
Engineering, 06.05.2020 08:34 seanholmes91405

An infinitely long rod (k= 200 Wm-'K-?) has a diameter of 40 mm. It is split in two halves, with one half of it exposed to ambient air at a temperature (T.,1) of 20 °C and a convective heat transfer coefficient (hi) of 5 Wm²K-1, and the other half of it exposed to water at a temperature (T.,2) of 15 °C and a convective heat transfer coefficient (h2) of 10 Wm-K-1 Joule heaters apply a heat rate (gb) to the rods at the air/water interface which then dissipates in both directions along the length of the rod. Determine the heat rate (9b) if temperature of the rods at their base (Tb) is 40°C. Assume that the surface emissivity of the rod is negligible. d= 40 mm k= 200 Wm-1K1 Air Toy = 20°C hy = 5 Wm-2K-1 91.1 Heater, 9. = ? 914.2 To = 40 °C Water T.2= 15°C ha= 10 Wm-2K-1

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Asingle-geared blanking press has a stroke of 200 mm and a rated capacity of 320 kn. a cam driven ram is assumed to be capable of delivering the full press load at constant force during the last 15 percent of a constant-velocity stroke. the camshaft has an average speed of 90 rev/min and is geared to the flywheel shaft at a 6: 1 ratio. the total work done is to include an allowance of 16 percent for friction a) estimate the maximum energy fluctuation b) find the rim weight for an effective diameter of 1.2 m and a coefficient of speed fluctuation of 0.10
Answers: 1
question
Engineering, 05.07.2019 23:20
Which one of the following faults cause the coffee in a brewer to keep boiling after the brewing cycle is finished? a. an open circuit in the heating element b. a short circuit at the terminals c. welded contacts on the thermostat d. a leak around the gasket
Answers: 3
question
Engineering, 06.07.2019 04:10
Aheat pump with refrigerant-134a as the working fluid is used to keep a space at 25°c by absorbing heat from geothermal water that enters the evaporator at 500c at a rate of 0.065 kg/s and leaves at 40°c. the refrigerant enters the evaporator at 20°c with a quality of 23 percent and leaves at the inlet pressure as saturated vapor. the refrigerant loses 300 w of heat to the surroundings as it flows through the compressor and the refrigerant leaves the compressor at 1.4 mpa at the same entropy as the inlet. determine: (a) the degrees of subcooling of the refrigerant in the condenser, b)-the mass flow rate of the refrigerant . (c) the heating load and the cop of the pump, and d)-the theoretical minimum power input to the compressor for the same heating load.
Answers: 3
question
Engineering, 06.07.2019 04:20
In modern manufacturing, which types of metal chips would be undesirable and why ? ?
Answers: 3
You know the right answer?
An infinitely long rod (k= 200 Wm-'K-?) has a diameter of 40 mm. It is split in two halves, with one...
Questions
question
Mathematics, 17.12.2020 01:50
question
Mathematics, 17.12.2020 01:50
question
Mathematics, 17.12.2020 01:50
question
History, 17.12.2020 01:50
question
Biology, 17.12.2020 01:50
question
Mathematics, 17.12.2020 01:50
Questions on the website: 13722367