subject
Engineering, 25.04.2020 01:12 hawaiisports8976

This problem assumes our standard unity (H(s) = 1) negative feedback closed-loop control system. The given open-loop transfer function is 2 ( ) ( 2) G s s s   . Using denominator parameter matching, design a PD (proportional-derivative) controller ( ) G s K Ks C PD   to achieve a closed-loop overdamped second-order response with 1s  2 and 2 s  4 . What is the resulting numerical closed-loop transfer function T(s)? For a unit step input R(s) and assuming 1.0 is the desired steady-state output value, determine the closed-loop correction factor, if one is required. Determine the pre-filter transfer function ( ) G s P , if one is required. Given a unit step input R(s), sketch the open-loop and input-corrected, pre-filtered closed-loop output responses, assuming zero initial conditions for both cases.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Aplate clutch has a single pair of mating friction surfaces 250-mm od by 175-mm id. the mean value of the coefficient of friction is 0.30, and the actuating force is 4 kn. a) find the maximum pressure and the torque capacity using the uniform-wear model. b) find the maximum pressure and the torque capacity using the uniform-pressure model.
Answers: 3
question
Engineering, 04.07.2019 18:10
Water at 55c flows across a flat plate whose surface temperature is held constant at 95c. if the temperature gradient at the plate's surface for a given value of x is 18 c/mm, find a) local heat transfer coefficient. b) heat flux
Answers: 3
question
Engineering, 04.07.2019 18:10
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
question
Engineering, 04.07.2019 19:10
Air inially occupying a volume of 1 m2 at 100 kpa, 27 c undergoes three internally reversible processes in series. process 1-2 compression to 500 kpa during which pv constant process 2-3 adiabatic expanslon to 100 kpa process 3-1: constant-pressure expansion to 100 kpa (a) calculate the change of entropy for each of the three processes. (b) calculate the heat and work involved in each process. (c) is this cycle a power cycle or refrigeration cycle?
Answers: 3
You know the right answer?
This problem assumes our standard unity (H(s) = 1) negative feedback closed-loop control system. The...
Questions
question
Mathematics, 12.08.2020 07:01
question
Mathematics, 12.08.2020 07:01
question
Biology, 12.08.2020 07:01
question
Biology, 12.08.2020 07:01
question
Mathematics, 12.08.2020 07:01
question
Mathematics, 12.08.2020 07:01
question
Mathematics, 12.08.2020 07:01
question
Mathematics, 12.08.2020 07:01
Questions on the website: 13722360