subject
Engineering, 24.04.2020 18:17 jacobgooding830

The 500- bed Lotta Hart Hospital has a small activated sludge plant to treat its wastewater. The average daily hospital discharge is 1500 L per day per bed, and the average soluble BOD5 after primary settling is 500 mg/L. The aeration tank has effective liquid dimensions of 10m wide by 10m long by 4.5m deep. The plant operating parameters areas follows: MLVSS =2500mg/L MLSS= 1.20 (MLVSS) Determine the following: aeration period, F/M ratio, SVI, solids concentration in return sludge. Using the following assumptions, determine the solids retention time, the cell wastage flow rate, and the return sludge flow rate for the Lotta Hart Hospital WWTP (Problem 1. ). Assume: Allowable BOD5 in effluent = 25 mg/L Suspended solids in effluent = 25 mg/L Wastage is from the return sludge line Yield coefficient = 0.60 mg VSS/mg BOD5 removed Decay rate of microorganisms = 0.060 d-1

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 12:10
On a average work day more than work place firs are reorted
Answers: 1
question
Engineering, 04.07.2019 18:10
Apump is used to circulate hot water in a home heating system. water enters the well-insulated pump operating at steady state at a rate of 0.42 gal/min. the inlet pressure and temperature are 14.7 lbf/in.2, and 180°f, respectively; at the exit the pressure is 60 lbf/in.2 the pump requires 1/15 hp of power input. water can be modeled as an incompressible substance with constant density of 60.58 lb/ft3 and constant specific heat of 1 btu/lb or. neglecting kinetic and potential energy effects, determine the temperature change, in °r, as the water flows through the pump.
Answers: 1
question
Engineering, 04.07.2019 18:10
Determine whether or not it is possible to compress air adiabatically from k to 140 kpa and 400 k. what is the entropy change during this process?
Answers: 3
question
Engineering, 04.07.2019 18:20
Along 8-cm diameter steam pipe whose external surface temperature is 900c connects two buildings. the pipe is exposed to ambient air at 70c with a wind speed of 50 km/hr blowing across the pipe. determine the heat loss from the pipe per unit length. (b) air at 500c enters a section of a rectangular duct (15 cm x 20 cm) at an average velocity of 7 m/s. if the walls of the duct are maintained at 100c. a) the length of the tube for an exit temperature of the air to be 40 0c. b)the rate of heat transfer from the air. c) the fan power needed to overcome the pressure drop in this section of the duct.
Answers: 1
You know the right answer?
The 500- bed Lotta Hart Hospital has a small activated sludge plant to treat its wastewater. The ave...
Questions
question
Mathematics, 13.09.2020 15:01
question
English, 13.09.2020 15:01
question
Mathematics, 13.09.2020 15:01
question
Mathematics, 13.09.2020 15:01
question
Mathematics, 13.09.2020 15:01
question
Mathematics, 13.09.2020 15:01
question
Mathematics, 13.09.2020 15:01
question
Mathematics, 13.09.2020 15:01
question
Mathematics, 13.09.2020 15:01
question
Mathematics, 13.09.2020 15:01
question
Mathematics, 13.09.2020 15:01
question
Mathematics, 13.09.2020 15:01
question
Mathematics, 13.09.2020 15:01
question
Mathematics, 13.09.2020 16:01
question
English, 13.09.2020 16:01
question
Geography, 13.09.2020 16:01
question
Mathematics, 13.09.2020 16:01
question
Mathematics, 13.09.2020 16:01
question
Mathematics, 13.09.2020 16:01
question
Mathematics, 13.09.2020 16:01
Questions on the website: 13722367