Engineering, 17.04.2020 18:33 chocolate1294

A building has the following dimensions and characteristics: footprint of 100 ft x 50 ft and 8 stories, 10 feet floor-to-floor height for each floor. The window-wall ratio is 33 Walls have an overall R-value of 20, windows have a U-value of 0.6. The roof has an R value of 30. Building is programmed as all office with 150 square feet per person

Part a

Calculate the design heating load, Q. in BTUH, assuming heating design conditions of 74 degree F inside and 10 degree Foutside and 15 CFM ventilation air per occupant.

Part b

Calculate the annual estimated fuel use in therms, assuming 3,800 degree-days (NYC), 80% efficient boiler, using natural gas at 100,000 BTU/Therm

Q windows annual =
Q wall annual =
Q roof annual
Q infiltration annual =

ansver
Answers: 1

Another question on Engineering

question
Engineering, 03.07.2019 14:10
Amass of 1.5 kg of air at 120 kpa and 24°c is contained in a gas-tight, frictionless piston-cylinder device. the air is now compressed to a final pressure of 720 kpa. during the process, heat is transferred from the air such that the temperature inside the cylinder remains constant. calculate the boundary work input during this process.
Answers: 2
question
Engineering, 04.07.2019 18:10
The flow rate of air through a through a pipe is 0.02 m5/s. a pitot static tube is placed in the flow. the radius of the pitot static tube is 1 mm. assuming the flow to be steady and the air to be at 300k, calculate the difference in total and static pressure if the diameter of the pipe is: (a) d 0.1 m d 0.05 m (c) d 0.01 m
Answers: 2
question
Engineering, 04.07.2019 18:20
Ahe-xe mixture containing a 0.75 mole fraction of helium is used for cooling electronics in an avionics application. at a temperature of 300 k and atmospheric pressure, calculate the mass fraction of helium and the mass density, molar concentration and molecular weight of the mixture. if the cooling capacity is 10 l, what is the mass of the coolant?
Answers: 3
question
Engineering, 04.07.2019 18:20
The characteristic roots of a dynamic system are: 1.7920 1.8160 i, -1.7920 1.8160 i, -0.4160 what is the order of this system? what are the settling time and damping ratio of the system?
Answers: 3
You know the right answer?
A building has the following dimensions and characteristics: footprint of 100 ft x 50 ft and 8 stori...
Questions
question
Social Studies, 15.12.2020 16:00
question
Mathematics, 15.12.2020 16:00
question
Social Studies, 15.12.2020 16:00
question
Computers and Technology, 15.12.2020 16:00
Questions on the website: 13722360