![subject](/tpl/images/cats/User.png)
Engineering, 15.04.2020 00:14 Kkampudiaa
The performance of a heat pump degrades (i. e., its COP decreases) as the temperature of the heat source decreases. This makes using heat pumps at locations with severe weather conditions unattractive. Consider a house that is heated and maintained at 26°C by a heat pump during the winter. What is the maximum COP for the heat pump if heat is extracted the out door air at 10 C?
![ansver](/tpl/images/cats/User.png)
Answers: 2
Another question on Engineering
![question](/tpl/images/cats/User.png)
Engineering, 03.07.2019 14:10
Amass of 1.5 kg of air at 120 kpa and 24°c is contained in a gas-tight, frictionless piston-cylinder device. the air is now compressed to a final pressure of 720 kpa. during the process, heat is transferred from the air such that the temperature inside the cylinder remains constant. calculate the boundary work input during this process.
Answers: 2
![question](/tpl/images/cats/User.png)
Engineering, 03.07.2019 14:10
Amass of m 1.5 kg of steam is contained in a closed rigid container. initially the pressure and temperature of the steam are: p 1.5 mpa and t 240°c (superheated state), respectively. then the temperature drops to t2= 100°c as the result of heat transfer to the surroundings. determine: a) quality of the steam at the end of the process, b) heat transfer with the surroundings. for: p1.5 mpa and t 240°c: enthalpy of superheated vapour is 2900 kj/kg, specific volume of superheated vapour is 0. 1483 m/kg, while for t 100°c: enthalpy of saturated liquid water is 419kj/kg, specific volume of saturated liquid water is 0.001043m/kg, enthalpy of saturated vapour is 2676 kj/kg, specific volume of saturated vapour is 1.672 m/kg and pressure is 0.1 mpa.
Answers: 3
![question](/tpl/images/cats/User.png)
Engineering, 03.07.2019 14:10
The y form of iron is known as: a) ferrite b) cementite c) perlite d) austenite
Answers: 3
![question](/tpl/images/cats/User.png)
Engineering, 03.07.2019 14:10
Line joining liquid phase with liquid and solid phase mixture is known as: a) liquidus b) solidus c) tie line d) none of the mentioned
Answers: 2
You know the right answer?
The performance of a heat pump degrades (i. e., its COP decreases) as the temperature of the heat so...
Questions
![question](/tpl/images/cats/himiya.png)
![question](/tpl/images/cats/istoriya.png)
![question](/tpl/images/cats/biologiya.png)
![question](/tpl/images/cats/biologiya.png)
![question](/tpl/images/cats/ekonomika.png)
Business, 01.07.2019 20:10
![question](/tpl/images/cats/istoriya.png)
![question](/tpl/images/cats/mat.png)
![question](/tpl/images/cats/mat.png)
![question](/tpl/images/cats/ekonomika.png)
![question](/tpl/images/cats/biologiya.png)
![question](/tpl/images/cats/istoriya.png)
![question](/tpl/images/cats/fizika.png)
![question](/tpl/images/cats/mat.png)
![question](/tpl/images/cats/informatica.png)
Computers and Technology, 01.07.2019 20:10
![question](/tpl/images/cats/mat.png)
![question](/tpl/images/cats/es.png)
![question](/tpl/images/cats/en.png)
![question](/tpl/images/cats/istoriya.png)
History, 01.07.2019 20:10
![question](/tpl/images/cats/mat.png)