Electric Resistance Heating. A house that is losing heat at a rate of 50,000 kJ/h when the outside temperature drops to 4 0C is to be heated by electric resistance heaters. If the house is to be maintained at 25 0C, determine the reversible work input for this process and the irreversibility.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Hydraulic fluid with a sg. of 0.78 is flowing through a 1.5 in. i.d. pipe at 58 gal/min. the fluid has an absolute viscosity of 11.8 x 105 lbf-sec/ft2. is the flow laminar, turbulent or within the critical range? give both a numerical reynolds number and a term answer.
Answers: 3
question
Engineering, 04.07.2019 19:20
At steady state, air at 200 kpa, 325 k, and mass flow rate of 0.5 kg/s enters an insulated duct having differing inlet and exit cross-sectional areas. the inlet cross-sectional area is 6 cm2. at the duct exit, the pressure of the air is 100 kpa and the velocity is 250 m/s. neglecting potential energy effects and modeling air as an 1.008 kj/kg k, determine ideal gas with constant cp = (a) the velocity of the air at the inlet, in m/s. (b) the temperature of the air at the exit, in k. (c) the exit cross-sectional area, in cm2
Answers: 2
question
Engineering, 04.07.2019 19:20
Ashielded metal arc-welding operation is accomplished in a work cell by a fitter and a welder. the fitter takes 5.5 min to load components into the welding fixture at the beginning of the work cycle, and 1.5 min to unload the completed weldment at the end of the cycle. the total ength of the weld seams 1200 mm, and the travel speed used by the welder averages 300 mm/min. every 600 mm of seam length, the welding stick must be changed, which takes 0.8 min. while the fitter is working, the welder is idle (resting): and while the welder is working the fitter is idle. (a) determine the average arc-on time as a fraction of the work cycle time. (b) how much improvement in arc-on time would result if the welder used flux-cored arc welding (manually operated), given that the spool of weld wire must be changed every 10 weldments, and it takes the welder 5.0 min to accomplish the change? (c) what are the production rates for these two cases (weldments completed per hour)? attach your work and solutions.
Answers: 1
question
Engineering, 06.07.2019 04:10
Cold water (cp=4180j/kg k) leadıng to a shower enters a thin-walled double-pipe heat transfer at 15c at a rate of 0.25kg/s and is heated to 45c by hot water (cp=4190j/kg k) that enters at 100c at the rate of 3kg/s. if the overall heat transfer coefficient is 950w /m2 k , determıne the rate of heat transfer and the heat transfer surface area of the heat exchanger using e - ntu method
Answers: 1
You know the right answer?
Electric Resistance Heating. A house that is losing heat at a rate of 50,000 kJ/h when the outside t...
Questions
question
Mathematics, 20.11.2020 18:00
question
Mathematics, 20.11.2020 18:00
question
Mathematics, 20.11.2020 18:00
question
Mathematics, 20.11.2020 18:00
question
Chemistry, 20.11.2020 18:00
Questions on the website: 13722363