subject
Engineering, 07.04.2020 15:45 mandoux

You have to design a queue management system for the customer relations department of a company. There is a waiting room from where customers go to the customer service area to have their issue addressed. Depending on the day, the number of customer service agents available can be from 1 to 8. There are sensors installed at the entrance which signal when someone enters the area or leaves it. Your system should use input from these to keep track of the number of customers in the area and signal if some service agent is available or not. Your inputs: C – the number of service agents available E – signal from sensor which pulses (goes from low to high and then back to low) when someone Enters the area L – signal from sensor which pulses (goes from low to high and then back to low) when someone Leaves the area Your outputs: A – availability. A one bit value that is high if someone is available, and low if all agents are occupied. You can assume that both E and L never pulse together. Please pay special attention to the notation used when solving the following questiona) Give the Extended FSM diagram of the systemb) Give the HLSM diagram of the system. c) Give the datapath circuit

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Burgers vector is generally parallel to the dislocation line. a)-true b)-false
Answers: 2
question
Engineering, 04.07.2019 18:10
Condition monitoring is a major component of. (clo4) a)- predictive maintenance. b)-preventive maintenance c)-proactive maintenance d)-reactive maintenance.
Answers: 1
question
Engineering, 04.07.2019 18:10
Compute the pressure drop of 30Β°c air flowing with a mean velocity of 8 m/s in a circular sheet-metal duct 300 mm in diameter and 15 m long. use a friction factor, f 0.02, and pair = 1.1644 kg/m a. 37.26 pa b. 25.27 pa n c. 29.34 pa d. 30.52 pa
Answers: 1
question
Engineering, 04.07.2019 19:20
To save energy, the air supply to a 2000 ft office has been shut off overnight and the room temperature has dropped to 40Β°f. in the morning, the thermostat is reset to 70Β°f and warm air at 120 f begins to flov in at 200ft'/min. the air is well mixed within the room, and an equal mass flow of air at room temperature (changing with time) is withdrawn through a return duct. the air pressure is nearly 1 atm everywhere. ignoring heat transfer with the surroundings and kinetic and potential energy effects, estimate how long it takes for the room temperature to reach 70Β°f. plot the room temperature as a function of time.
Answers: 1
You know the right answer?
You have to design a queue management system for the customer relations department of a company. The...
Questions
question
History, 16.02.2020 05:44
question
Mathematics, 16.02.2020 05:46
question
Mathematics, 16.02.2020 05:50
question
Mathematics, 16.02.2020 05:50
Questions on the website: 13722363