Engineering, 21.03.2020 09:11 coollid876

Chlorine is used to disinfect a flow of 0.20 m3/s water in a municipal drinking water treatment plant, which operates an ideal plug-flow reactor with a 185 m^3 volume. The chlorine concentration is assumed to be constant throughout the reactor. Giardia, a problematic cyst-forming pathogen, is reduced by 99.9% by 2.50 mg/L HOCl. Plant operators normally keep the pH at 6.00 for the disinfection process.
If r(N) = -k*N and k* = kC, what are the values of k* and k?
Given the dissociation reaction below with a dissociation constant Ka = 10-7.54, how much OCl⁻ will be in solution in the disinfection process above? What is the total molar concentration of chlorine?
HOCl ↔ Hâș + OCl⁻

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Apump is used to circulate hot water in a home heating system. water enters the well-insulated pump operating at steady state at a rate of 0.42 gal/min. the inlet pressure and temperature are 14.7 lbf/in.2, and 180°f, respectively; at the exit the pressure is 60 lbf/in.2 the pump requires 1/15 hp of power input. water can be modeled as an incompressible substance with constant density of 60.58 lb/ft3 and constant specific heat of 1 btu/lb or. neglecting kinetic and potential energy effects, determine the temperature change, in °r, as the water flows through the pump.
Answers: 1
question
Engineering, 04.07.2019 18:10
Determine whether or not it is possible to compress air adiabatically from k to 140 kpa and 400 k. what is the entropy change during this process?
Answers: 3
question
Engineering, 04.07.2019 18:10
The thermal expansion or contraction of a given metal is a function of the f a)-density b)-initial temperature c)- temperature difference d)- linear coefficient of thermal expansion e)- final temperature f)- original length
Answers: 2
question
Engineering, 04.07.2019 18:10
Which of the following ziegler nichols tuning methods the response of the controller to a step input should exhibit an s-shaped curve? a)-open loop mode b)-closed loop mode c)-both modes (open & closed) d)-none of the modes (open & closed)
Answers: 3
You know the right answer?
Chlorine is used to disinfect a flow of 0.20 m3/s water in a municipal drinking water treatment plan...
Questions
question
Business, 02.02.2021 22:40
question
Mathematics, 02.02.2021 22:40
question
Mathematics, 02.02.2021 22:40
question
English, 02.02.2021 22:40
question
Mathematics, 02.02.2021 22:40
question
Mathematics, 02.02.2021 22:40
question
Mathematics, 02.02.2021 22:40
Questions on the website: 13722362