A two-unit separation is used to dewater ethanol. First, a 110 mol/hr feed of a mixture of 0.750-mole fraction ethanol (E) and the balance water (W) is distilled. The extractive agent, benzene (B), is added to the distillation column in a mixture of 0.940-mole fraction benzene (0.060-mole fraction water). This mixture consists of fresh benzene and the recycle stream of benzene and water recovered from the separator. The company wishes to produce 0.995-mole fraction ethanol (0.005-mole fraction benzene) product stream from the overhead of the distillation column. The bottoms product, containing just benzene and water, is sent to the separator. The composition of the benzene/water mixture leaving the bottom of the separator is 0.85-mole fraction benzene and the balance water. Some of the bottom stream leaving the separator is recycled and added to the fresh benzene feed to the column and the rest of the bottom stream (121 mol/hr) is sent to another unit (not included in this analysis). The stream leaving the top of the separator is pure water.
Draw and label a process flow diagram for this process. Number each stream. Clearly label the components (E, W, B) in each stream. Calculate the flow rate (mol/hr) of all unknown streams entering and exiting the system. Calculate the flow rate (mol/hr) and mole fractions of the stream exiting the bottom of the distillation column. The stream leaving the top of the separator is an ideal gas at 22 psig and 190 degrees C. Calculate the volumetric flow rate (cm^3/s) of this stream.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 03:10
What precautions should you take to prevent injuries when dealing with heavy loads?
Answers: 1
question
Engineering, 04.07.2019 18:10
Which one from below is not one of the reasons of planning failures? (clo3) a)-planner is careless. b-planner spend less time in the field but more time on the desk c)-planner is not qualified d)-planner does not have sufficient time to properly plan
Answers: 3
question
Engineering, 04.07.2019 18:20
Athin walled concentric tube exchanger is used to cool engine oil from 160°c to 60°c with water that is available at 25°c acting as a coolant. the oil and water flow rates are each at 2 kg/s, and the diameter of the inner tube is 0.5 m and the corresponding value of the overall heat transfer coefficient is 250 w/m2. oc. how long must the heat exchanger be to accomplish the desired cooling? cpwater=4.187 kj/kg-candcpengine el=2.035 kj/kg·°c, oil . 120]
Answers: 1
question
Engineering, 06.07.2019 04:20
What is the fuid acceleration in vector form for the following velocity field? note i, j, and k are unit vectors. show all of your work.
Answers: 1
You know the right answer?
A two-unit separation is used to dewater ethanol. First, a 110 mol/hr feed of a mixture of 0.750-mol...